The SEVCD-33 is a low leakage airfoil blade control damper with 316 stainless steel construction. The applications are in medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ 4-8 in. wg Velocity: Up to 4000 fpm Temperature: Up to 250°F Blade
The SEVCD-23 is a low leakage 3V blade control damper with 316 stainless steel construction. The intended applications are in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg; Class 1 @ up to 5 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The intended use for FBV-23 face and bypass control dampers are in low to medium pressure and velocity systems. The control damper features 3V blades and is IECC (International Energy Conservation Code) compliant. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1 in. wg; Class 1 @ up to 5 in. wg Veloc
The VCDRM-53 is an insert type multi-blade round control damper providing airflow control in round HVAC ductwork. This damper has applications in low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: 3½ cfm per sq. foot @ 1 in. wg Velocity: Up to 2500 fpm Temperature: Up to
Model ICD-45 is low leakage control damper with aluminum extruded blades and frame that are insulated and thermally broken. The model minimizes the transfer of thermal energy and reduces condensation. It meets the requirements of IECC (International Energy Conservation Code). Pressure: Up to 8 in.
The ICD-44 is a low leakage control damper with aluminum extruded blades that are thermally broken. The control damper minimizes transfer of thermal energy and reduces condensation. It meets the requirements of IECC (International Energy Conservation Code). Pressure: Up to 8 in. wg Leakage: Class 1
The VCDR-53 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Leakage: 4 cfm per sq. foot @ 1 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F Blade seal
The VCDR-50 round control damper is for applications in low to medium pressure and velocity systems. Pressure: Up to 4 in. wg Velocity: Up to 3000 fpm Temperature: Up to 250°F
The VCD-43 control damper is low leakage with extruded aluminum airfoil blades and frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8
The VCD-33 is a low leakage control damper with fabricated airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in. wg Velocit
The VCD-23 is a general purpose control damper with 3V blades. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Velocity: Up to 3
The VCD-42 is a low leakage control damper with extruded aluminum airfoil blades. This damper can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 6 in. wg Leakage: 3 cfm per sq. foot @ 1in. wg, 6 cfm per s
Model VCD-40 is a low leakage control damper that has blades completely contained within the 4 in. frame. This allows the direct mount to a louver, filter frame, or similar application with no blade interference. Pressure: Up to 6 in. wg Leakage: Class 1A @ 1 in. wg Velocity: Up to 6000 fpm Tempera
The VCD-34 is a low leakage control damper that has insulated fabricated airfoil blades. The damper works well in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ 4-8 in
The VCD-20 is a general purpose control damper with 3V blades. This damper can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Velocity: Up to 3000 fpm Temperature: -40°F to 250°F
The VCD-23V control damper has vertical 3V blades with blade and jam seal. This model can be used in applications as an automatic control or manual balancing damper with low to medium pressure and velocity systems. Pressure: Up to 5 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up to 5 in. wg Veloc
The VCD-43V control damper has low leakage with extruded aluminum airfoil blades and an aluminum frame. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg,
The VCD-34V is a low leakage control damper with insulated vertical fabricated airfoil blades. This model can be used in applications as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @
The VCD-33V is a low leakage control damper with vertical fabricated airfoil blades. The model can be used as an automatic control or manual balancing damper with medium to high pressure and velocity systems. Pressure: Up to 8 in. wg Leakage: Class 1A @ 1in. wg, Class 1 @ up 4-8 in. wg Velocity: Up
The RBE belt-driven axial fan is ideal for roof-mounted applications exhausting relatively clean air. These units feature fabricated steel propellers and a fabra hood-style housing. 1,340 to 82,283 cfm Up to 1.5 in. wg.
Model AE is a direct drive fan designed for roof mount applications exhausting relatively clean air. Fans feature spun aluminum housings and fabricated aluminum propellers. 250 to 6,000 cfm Up to 1.0 in. wg.
An RBCE belt drive, roof mounted axial fan is for applications exhausting relatively clean air. Fan propellers are cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 830 to 78,000 cfm Up to 1. 0 in. wg.
The RE2 has fabricated steel propellers with a fabra hood-style aluminum or steel housing. The unit is a direct drive, roof mount axial fan for applications exhausting relatively clean air. 1,200 to 41,470 cfm Up to 2.0 in. wg.
Model RCE3 is a direct drive, roof mount axial fan designed for applications exhausting relatively clean air. Fan propellers are cast aluminum airfoil blades, with fabra hood-style aluminum or steel housings. 580 to 42,290 cfm Up to 1.5 in. wg.
Model XG-STBPF is a steel T-bar plaster frame.
Model XG-TBPF is an aluminum T-bar plaster frame.
Model XG-TBPFMK is a mounting kit for use with the lay-in or T-bar plaster frames.
Model XG-L9 is an aluminum equalizing grid.
Model XG-TR is a steel square to round transition.
Model XG-TR-DEEP-AL is a deep aluminum square to round transition for use with grille/diffusers that have factory mounted dampers.
Model XG-TR-AL is an aluminum square to round transition.
Model XG-TR-DEEP is a deep steel square to round transition for use with grille/diffusers that have factory mounted dampers.
Model XG-BAF-12 is a single directional baffle for use with series XG-5700/XG-5800 diffusers. 12x12 Module size.
Model XG-BAF-24 is a single directional baffle for use with series XG-5700/XG-5800 diffusers. 24x24 Module size.
Model XG-BO is a single blank off for use with model XG-5750 diffusers.
Model XG-SNAP-58 is a center cone used to convert a model XG-5700 to a model XG-5800 diffuser.
Model XG-BDS is a steel round butterfly damper.
Model XG-D3 is an aluminum round radial opposed blade damper.
Model XG-SD3 is a steel round radial opposed blade damper.
Model XG-RSD is a steel radial shutter damper.
Model XG-RSD-TR is a steel radial shutter damper neck mounted in transition.
Model XG-D5 is a face operated steel opposed blade damper for use with series XG-5500 diffusers.
Model XG-D7A is a face operated aluminum opposed blade damper for use with series XG-7000 diffusers.
Model XG-D7 is a face operated steel opposed blade damper for use with series XG-7000 diffusers.
Model XG-G3 is a round, aluminum equalizing grid.
Model XG-G3 is a round, aluminum equalizing grid with butterfly damper.
Model XG-G3 is a round, aluminum equalizing grid with radial shutter damper.
Model XG-TBP-5000 is an aluminum lay in panel for use with Model XG-5500 diffusers.
Model XG-TSPF is an aluminum T-bar plaster frame with tape and spackle frame.
Model XG-FGBP is a molded 2'x2' fiberglass insulation backpan.