Number of Results: 474
Model XG-UPI is a galvanized steel insulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-UP is a galvanized steel uninsulated universal plenum for use with linear diffusers or grilles, available in 24, 36, 48, 60, or 72-inch standard lengths and a 10.5-inch standard height.
Model XG-TH-500 is the simplest and most widely used variable air volume (VAV) terminal unit. Its primary function regulates airflow to an occupied space. Capacities ranging from 80-7,270 cfm in 10 sizes. Pneumatic, electric, analog, or direct digital controls available. Hot water or electric heat
Model XG-AFL-TSI is an extruded aluminum architectural linear slot diffuser tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model HLC-FPS is a self-contained fan filter module that has the highest CFM output in the industry. Units connect directly to system ductwork and are simple to install in a ceiling grid or hard ceilings. Product Features: Quiet operation – only NC-46 - NC-51 at 90 feet per minute Airflow rates up
Model XG-AFL-TSBI is an extruded aluminum architectural linear slot diffuser bolt slot tee system (insulated), available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-AFL-TSB is an extruded aluminum architectural linear slot diffuser bolt slot tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model XG-CC1 is an aluminum sidewall or ceiling return/exhaust grille with one-inch x one-inch x one-inch cube core designed to provide low pressure drops and low sound levels. Available in 3-week Industry-leading lead times.
Model XG-AFL-TS is an extruded aluminum architectural linear slot diffuser tee system, available in one-inch to two-inch slot widths, one or two slots, and 24, 48, or 60-inch lengths.
Model HLC-FFR radial discharge pattern diffusers are engineered for supply air distribution in critical environments such as chemistry labs and clean rooms. The diffusers are engineered to supply a low velocity of conditioned air in a radial pattern from the ceiling. Product Features: Low velocity
The design of model XG-LFL is for continuous length applications where the clean lines of a louver face diffuser are desirable.
Model XG-MRDD is an aluminum round architectural double deflection grille with individually adjustable deflection blades.
Model XG-MRDDW is an aluminum round architectural double deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MREC is an aluminum round architectural egg crate grille.
Model XG-MRPF is an aluminum round architectural perforated grille.
Model XG-MRSD is an aluminum round architectural single deflection grille with individually adjustable deflection blades.
Model XG-MRSDW is an aluminum round architectural single deflection grille with individually adjustable deflection blades and wide blade spacing.
Model XG-MPK is an aluminum punkah louver that discharges a directable high-velocity jet to condition a specific space or area.The XG-MPK is constructed using a felt gasket that allows smooth movement of the inner core to direct air flow and provide a tight seal to prevent air leakage.
Model XG-JA diffusers are an excellent choice for high-capacity, long throw applications. The modular design of the XG-JA allows selection for a wide range of air volumes.
Model XG-EPRHF is a plastic 2 foot x 2 foot lay-in louver face filter return grille with 1 inch deep filter rack.
Model XG-EPRH is a plastic 2 foot x 2 foot lay-in louver face return grille.
The SSSMDR-501 is a Class I leakage-rated round smoke damper constructed of 304 stainless steel. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 350°F
The SSFD-350 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
The SSFD-150 is a 304 stainless steel static rated fire damper for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature
Model SSDFD-350 is for use in walls and partitions with fire-resistance ratings of three hours or more. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are used with HVAC systems that remain operational during a fire emergency. 304 stainless steel construction Pressure: Up to 4 in. w
Model SSDFD-150 is for use in walls and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocit
The SESMD-201 is a Class I leakage rated smoke damper constructed of 316 stainless steel with 3V blades. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The OFD-150 is an out-of-wall fire damper for use in HVAC systems that automatically shut down in the event of a fire. This model is rated for use in walls or partitions with less than a three hour fire-resistance rating. Temperature: Up to 212°F
Model ODFD-150 is an out-of-wall fire damper for use in walls or partitions with less than three hour fire-resistance rating. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: Up to 286°F
The CFSD-211 is a combination fire smoke damper for corridor ceiling applications and has UL 555 1 hour fire rating and UL 555S leakage class I. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F 10-Day Fixed Lead Times on Select Configurations. Watch Now to Learn More!
Model DFDAF-330 is a multi-blade dynamic-rated-fire damper with airfoil style blades for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. Dynamic-rated-fire dampers are used with a HVAC systems that remain operational during a fire emergency. Pressure: Up to
Model DFDAF-310 is a multi-blade airfoil dynamic-rated-fire damper used in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 8 in. wg Velocity: Up to 4000 f
Model GFSD-211 is an out of wall combination fire smoke damper with 3V blades. Its design allows for easy access through the grille to the damper, closure device, and the actuator. This model can install vertically or horizontally and is rated for airflow and leakage in either direction. UL 555 1½
Model OFSD-311 is an out-of-wall combination fire smoke damper with airfoil blades. It is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure
Model OFSD-212 is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
Model OFSD-211 is approved for use in walls, partitions, and floors with fire-resistance ratings less than three hours. This combination fire smoke damper allows for easy access through the grille to the damper, closure device, and actuator. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Tempera
Model SEDFD-210 is a 3V multi-blade-fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 316 stainless steel construction Pressure: Up to 10 in. wg Velo
The SEFSD-211 is a severe environment 316SS combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 316 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up
Model SSDFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up
The SSFSD-211 is a 304 stainless steel combination fire smoke damper with 3V blades. This model installs in walls, floors, or partitions and is rated for airflow and leakage in either direction. 304 stainless steel construction Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 35
The SSSMD-201 is a Class I leakage rated smoke damper with 304 stainless steel construction and 3V blades. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: Up to 350°F
The SSFSDR-511 has round blades. This model installs in walls, floors, and partitions and is rated for airflow and leakage in either direction. 304 stainless steel construction Pressure: Up to 4 in. wg Velocity: Up to 4000 fpm Temperature: 350°F
The CRD-1 is an ETL Listed damper designed to limit radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-1LP is a UL 555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less. This model is intended for use on applications with limited blade clearance.
The CRD-1 is a UL555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-2 is a UL555C classified damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less.
The CRD-1WT is a UL 555C classified damper for installation in wood truss construction with ratings up to one hour. These assemblies are given proprietary design numbers listed in the UL Fire Resistance Directory.
The CRD-1LP is an ETL Listed damper designed to limit the radiant heat transfer through an opening in the ceiling membrane of a fire-resistance rated floor/ceiling assembly of three hours or less. This model is intended to be used on applications with limited blade clearance.
The CRD-1WJ is a UL 555C classified damper for installation in wood joist construction. These assemblies are given proprietary design numbers listed in the UL Fire Resistance Directory.
The CRD-501 is a round UL555C classified damper with UL555S leakage class I rating.