Number of Results: 77
The SMD-201M is a Class I rated modulating smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperatur
The SMD-201 is a Class I leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature: U
The SMD-202 is a Class II leakage rated smoke damper with 3V blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to 2000 fpm Temperature:
The SMD-302M is a Class II leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Tempera
The SMD-302 Class II leakage rated smoke damper has airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-301V is a Class I leakage rated smoke damper with vertical airfoil blades for operational closure in emergency smoke control situations. This model installs vertically and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperature: Up
The SMD-401M is a Class I leakage rated modulating smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velo
Model DFDR-510 is a round fire damper for use in walls, floors, and partitions with fire-resistance ratings less than three hours. Dynamic-rated-fire dampers are in HVAC systems that remain operational in the event of a fire. Pressure: Up to 4 in. wg Velocity: Up to 2000 fpm Temperature: Up to 286°
The SMD-401EF is a Class I leakage rated smoke damper with extruded aluminum airfoil blades and frame for operational closure in emergency smoke control situations. The damper installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velo
The SMD-301M is a Class I leakage rated modulating smoke damper with airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 4 in. wg Velocity: Up to 2000 f
The SMD-401 is a Class I leakage rated smoke damper with extruded aluminum airfoil blades for operational closure in emergency smoke control situations. This model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 6 in. wg Velocity: Up to
The SMD-301 is a Class I leakage rated smoke damper with airfoil blades for operational closure in emergency smoke control situations. The model installs vertically or horizontally and is rated for airflow and leakage in either direction. Pressure: Up to 8 in. wg Velocity: Up to 4000 fpm Temperatur
Model FD-310 is for use in walls, floors, and partitions with fire resistance ratings of three hours or more. This model has a 2³/₁₆ inch frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-350 is for use in walls, floors, and partitions with fire-resistance ratings of three hours or more. This model is UL 555 classified with a 3¹¹/₁₆-in. frame. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
The FD-150X series is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has an integral sleeve. Static-rated-fire dampers used in HVAC systems that automatically shut down in the event of a fire emergency. Temperature: Up to 212°F FD-150x12 has
The FD-150 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 3¹¹/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire emergency. Temperature: Up to 212°F
Model FD-110 is for use in walls, floors, and partitions with fire-resistance ratings less than three hours. This model has a 2³/₁₆ inch frame. Static-rated-fire dampers used in HVAC systems automatically shut down in the event of a fire. Temperature: Up to 212°F
The KFD-150 is a static rated fire damper used in kitchen ventilation systems. This model has a fire-resistance rating of less than three hours. Static rated fire dampers are used in systems that automatically shut down in the event of a fire emergency.
The KFD-350 is used in kitchen ventilation system with a fire resistance rating of 3 hours or more. Static rated fire dampers used in HVAC systems automatically shut down in the event of a fire emergency.
The USF has many construction configurations to choose from. Galvanized Construction: This is going to be the most economical fan available for its performance range. Constructed of heavy gauge galvanized steel, these fans are available in direct or belt drive arrangements. Coated Steel Constructio
In most instances, plug fans are unhoused and rely on the plenum space around the backward-inclined centrifugal wheel to direct airflow as required in the system. Model PLG is available in belt or direct drive with steel, aluminum or 316 stainless steel constructions. 900 to 71,000 cfm per fan Up t
Model FPB is a pressure blower that uses a radial aluminum blade wheel providing efficient operation and spark resistant construction. Housing design is fully rotatable and constructed of steel with a baked polyester coating. All models are direct drive, arrangement 4 with wheels directly connected
Model BCSW-FRP is a single width FRP centrifugal blower that includes a backward-curved wheel and features a controlled laminate construction with a layer of ‘C’ veil as standard. This complies with ASTM D4167 and ASTM C582 specifications. The unit is available in belt or direct drive versions. Add
Greenheck industrial process fans are engineered and built for reliable operation in severe environments where high temperatures and static pressures, and material handling requirements are encountered. Model IP uses three different wheel designs and four construction levels to meet specific industr
Model XG-2300CO is an extruded aluminum core only linear bar grille with 1/8-inch bars on 1/4-inch centers, available with 0°, 15°, or 30° blade deflection.
Model XG-2300 is an extruded aluminum linear bar grille with 1/8-inch bars on 1/4-inch centers and one-inch flanged frame, available with 0°, 15°, or 30° blade deflection.
Model XG-2300MC is an extruded aluminum linear bar grille mitered corner section with 1/8-inch bars on 1/4-inch centers and one-inch flanged frame, available in 90°, 135° or special angles (SA) with 0°, 15°, or 30° blade deflection.