  • HCD-135

    "HCD-135 Industrial Control Damper W x H Minimum Size Maximum Size Single Section Multi - Section Inches 10 x 5 60 x 96 120 x 96 mm 254 x 127 1524 x 2438 3048 x 2438 Size Limitations H* W* D C * Actual Inside Dimension. The W dimension is ALWAYS parallel with the damper blade length. Damper linkage

  • HBTR-451

    The HBTR-451 is an isolation damper designed for isolation and decontamination applications. The damper has bubble tight leakage performance per AMCA 500-D up to 30 in. wg (7.5 kPa). The damper frame is flanged for easy mounting and the blade seal is mechanically fastened to the blade. *Actual Insid

  • DFDR-510

    See complete marking on product. UL 555 Classification R13317 These dimensions are furnished approximately 1⁄8 in. (3mm) undersize. 2 in. TW AIRFLOW SLEEVE LENGTH 2 in. 6 in. max.6 in. max. (OPTIONAL) RETAINER PLATE DUCT CONNECTION AREA CLEARANCE FOR EXPANSION RETAINER PLATE BLADE LATCH ACCESS DOOR

  • Wall Bracket (#483966 IOM)

    Wall Bracket 1 Document 483966 Wall Bracket Centrifugal Upblast Exhaust, Sizes 060-300 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protec

  • EMV-11

    The EMV-11 is a horizontally mounted backdraft damper that is designed to allow vertical airflow up and prevent reverse airflow. The damper is opened by air pressure differential and closed by gravity. Standard models include adjustable counterbalance to assist opening. *W H dimensions furnished app

  • July 2022 class descriptions

    HVAC University Course Descriptions Classes • July 11, 12-1 p.m., CDT – Warehouse Ventilation Strategies and Design Considerations • July 12, 12-1 p.m., CDT – Ventilation Strategies Utilizing Ceiling Exhaust and Bathroom Exhaust Fans to Meet Indoor Air Quality Requirements Warehouse Ventilation Stra

  • August2022classdescriptions

    HVAC University Course Descriptions Classes • August 30, 12-1 p.m., CDT – Increasing Design Efficiency Using Software • August 31, 12-1 p.m., CDT – Understanding AMCA 500-L Louver Weather Testing and FEMA 361 Tornado Shelters Increasing Design Efficiency Using Software This course discusses how to b

  • Brochure: Danish Technological Institute (DTI) Test Results

    Powerful Disinfection, AMPLIFY™ WITH NORTHERN LIGHT® TECHNOLOGY IS PROVEN TO INACTIVATE 95% OF MS2 VIRUS* IN A REAL-WORLD APPLICATION. * MS2 virus contains an ssRNA (Single Stranded Ribonucleic Acid) genome similar to SARS-CoV-2 (coronavirus). Unlike competitor air cleaning products that are tested

  • Draw-Thru vs Blow-Comparison

  • Application: Fan Service Training

    Fan Maintenance Service Training Application (10/16) Page 1 of 1 Copyright © 2016 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Fan Maintenance Service Training Application Course Description: A two-day, hands-on fan maintenance seminar that covers

  • GH_CORP Warehouse Rep 2 Pg Sheet

    1 3 3 2 2 2 2 4 4 5 5 6 7 11 10 10 12 8 9 n SINGLE SOURCE n EASY SELECTION n ENERGY EFFICIENT Delivering the Total Package Greenheck provides complete ventilation systems for distribution centers. Greenheck is the single source that delivers all of the air movement, conditioning and control equipmen

  • White Paper: Does Your Exhaust Fan Suck?

    "&$//86_6:,17(5&201(: 25.  1 _ :$6+,1*721 '&_ 125:$/. &7 ‹6WHYHQ:LQWHU $VVRFLDWHV,QF 'RHV RXU([KDXVW)DQ6XFN"" 6ULNDQWK3XWWDJXQWD_6WHYHQ:LQWHU$VVRFLDWHV,QF )HEUXDU\ $EVWUDFW RXOLNHO\GRQ·WHYHQWKLQNDERXWLWZKHQXVLQJWKHEDWKURRP)OLSWKHVZ

  • Webinar: Tempered Air Products - Base Package Offering in CAPS 4.34

    Webinar Training November 17, 2020 Tempered Air Products – Base Package Offering in CAPS® 4.34 As part of Greenheck’s continuing innovation for make-up air solutions, we are excited to introduce a new “base package” offering to the direct gas-fired DGX-H12. We currently offer two direct gas-fired mo

  • March 2022 class descriptions

    HVAC University Course Descriptions Classes • March 15, 12-1 p.m., CDT – Proper Application and Specification of Ceiling Radiation Dampers and Ceiling Radiation Damper- Ceiling Exhaust Fan Combinations • March 16, 12-1 p.m., CDT – Make-Up Air Ventilation • March 22, 12-1 p.m., CDT – Warehouse Ventil

  • Northpoint Development MUA Sizing Tool

  • Greenheat Competitor Comparison

    Greenheat Competitive Comparison and Sales StrategiesWhat is “Greenheat”?Model DGX make-up air units optimized for space heatingDirect gas fired heating (92% efficient)100% outside air140F max temp rise and leaving air tempFixed sizes that optimize cost per BTUHow do they work?Generally cycle on dem

  • Vektor-H Direct Drive Update

    Bulletin: 29-22 TO: All Greenheck Representatives FROM: Matt Gaedtke Segment Manager, Laboratory and Fume Exhaust Systems DATE: June 6, 2022 SUBJECT: Vektor-H Direct Drive Update Vektor®-H Direct Drive Reduces Power and Maintenance We continue to see growth in our new Vektor-H direct drive (VK-H Arr

  • December_2021_class_descriptions

    1 HVAC University Course Descriptions Classes • December 1, 12-1 p.m., CST – Kitchen Ventilation Systems: Meeting Codes and Standards • December 2, 12-1 p.m., CST – HVLS Fan Design, Application and Specification • December 6, 12-1 p.m., CST – Conditioning High Percentages and 100% Outdoor Air • Dece

  • February 2022 class descriptions

    1 HVAC University Course Descriptions Classes • February 2, 12-1 p.m., CST – Kitchen Ventilation Systems: Meeting Codes and Standards • February 3, 12-1 p.m., CST – Conditioning High Percentages and 100% Outdoor Air • February 15, 12-1 p.m., CST – Life Safety Dampers • February 16, 12-1 p.m., CST –

  • Vari-Green® Harness and Motor Information

  • October 2021 Greenheck HVAC University Classes

    1 HVAC University Course Descriptions Classes • October 5 – HVLS Fan Design, Application and Specification • October 6 – Ventilation Strategies Utilizing Ceiling Exhaust and Bathroom Exhaust Fans to Meet Indoor Air Quality Requirements • October 7 – Life Safety Dampers • October 12 – Air-to-Air Ener

  • Coop Trade Support

    2636520307901Greenheck Fan Corporation Policy to Support Local Trade Shows 00Greenheck Fan Corporation Policy to Support Local Trade Shows International Representative OfficesDate: June 2020Policy:Greenheck allows for the joint promotions in support of trade shows of the representative office and Gr

  • SP-CSP Power Ratings, Motors and Certifications

    P.O. Box 410 • Schofield, WI 54476-0410 • Phone (715) 359-6171 • greenheck.com Copyright © 2021 Greenheck Fan Corp. | November 2021 SP Model 115V/ 60Hz 115V/ 50Hz 220240V/ 50Hz 220240V/ 60Hz 277V EC Motor HP Motor 1 ASHRAE 90.1 Compliant SP-A50 304923 1/625 Yes SP-A70 317723 2.25/746 Yes SP-A90 3122

  • Power of the Package Sales Sheet

    Power of the Package Greenheck’s comprehensive line of ventilation products just got even better! With the addition of grilles, registers, diffusers (GRDs) and air terminal units (ATUs), you can now specify products from rooftop to entryway from one trusted single-source supplier. CONTACT YOUR GREEN

  • QB Roof Curb Multiplier Schedule - E.H. Price and Global Mechanical

    1 Effective: 04/04/2022 CAPS Version: 4.38.923 QB Roof Curb Multiplier Schedule EH Price Global Mechanical Confidential Multiplier Schedule

  • November 2021 Greenheck HVAC University Classes

    HVAC University Course Descriptions Classes • November 2 – Proper Application and Specification of Ceiling Radiation Dampers and Ceiling Radiation Damper- Ceiling Exhaust Fan Combinations • November 3 – Make-Up Air Ventilation • November 4 – COVID Mitigation Strategies Utilizing HVAC Systems • Novem

  • Air Terminal Units FAQ Sheet

    FAQ SHEET December 2021 Can we factory-mount controls from any controls manufacturer? Yes, we can mount controls from any manufacturer. However, in rare instances the standard enclosure is too small for large controllers, so there would be additional charges required for an oversized control enclosu

  • April 2022 class descriptions

    HVAC University Course Descriptions Classes • April 5, 12-1 p.m., CDT – COVID Mitigation Strategies Utilizing HVAC Systems • April 13, 12-1 p.m., CDT – Motor Technology in the HVAC Industry • April 19, 12-1 p.m., CDT – Kitchen Ventilation Systems: Meeting Codes and Standards • April 20, 12-1 p.m., C

  • 1 HVAC University Course Descriptions Classes • January 4, 12-1 p.m., CST – Proper Application and Specification of Ceiling Radiation Dampers and Ceiling Radiation Damper- Ceiling Exhaust Fan Combinations • January 5, 12-1 p.m., CST – Understanding AMCA 500-L Louver Weather Testing and FEMA 361 Torn

  • GH_CORP_Mini MLC Flier

    Greenheck’s HVAC University Learning Center is hitting the road to deliver warehouse ventilation solutions to you. Your educational resource! A warehouse or distribution center is not your typical building—large doors and loading bays that are often open in any weather; gas-powered vehicles operatin

  • 1682 DOAS_MUA Training_2022

    DOAS and Make-Up Air Service Training Dates: April 25-26, 2022 July 27-28, 2022 April 27-28, 2022 September 12-13, 2022 July 25-26, 2022 September 14-15, 2022 Min Class Size: 8 Max Class Size: 16 Course Objectives: • Become fully capable of properly starting up Greenheck Make-Up Air (MUA) and DOAS e

  • Greenheck_HVAC_registration_form_2022

    HVAC University Registration Form Please return the completed form to your Greenheck representative. Name on Driver’s License Date of Seminar: Badge Name: Date of Birth: Firm/Business Name: Address: City: State: Zip: Phone No. ( ) Fax #: ( ) Email: Company website: Tell us about your company: 1. ___

  • Frequently Asked Questions

    FAQ SHEET October 2021 What is Northern Light® technology? Northern Light is a patented technology that combines AMPLIFY™ overhead HVLS fans with UV-C light to inactivate airborne viruses and bacteria. Why would I want UV-C lights on an overhead fan? Upper room UV lighting systems (also known as UVG

  • Technical Sheet: Northern Light

    PRIMARY APPLICATIONS Education Facilities | Automotive Garages or Dealerships Police and Fire Stations | Retail Stores | Restaurants and Bars | Fitness Centers Offi ce Spaces | Warehouses | Distribution Centers | Aviation Facilities Airports AMPLIFY™ with Northern Light® technology combines the air c

  • PowerPoint template

    The Next Generation of Overhead FansGet ready to boost your HVLS Sales!AMPLIFY™ Taking Comfort to New Heights

  • QD Model Replacement Parts List: SP-B50, 70, 80, 90, 110, 150, 200

    QD Model Replacement Parts List: SP-B50, 70, 80, 90, 110, 150, 200 Replacement Part Numbers Size Motor 115V Power Pack SP-B50-QD 315037 873436 SP-B70-QD 315038 873437 SP-B80-QD 315039 873438 SP-B90-QD 314955 873439 SP-B110-QD 310145 873440 SP-B150-QD 310198 873441 SP-B200-QD 302424 873442 * Parts in

  • GH_CORP Mini MLC Trifold Handout

    Delivering Warehouse Ventilation Solutions to You Greenheck is the single source that delivers all of the air movement, conditioning and control equipment needed for warehouse and distribution center ventilation systems. We make it easy to specify integrated systems that: • Create a safe and product

  • May 2022 class descriptions

    HVAC University Course Descriptions Classes • May 2, 12-1 p.m., CDT – Warehouse Ventilation Strategies and Design Considerations • May 3, 12-1 p.m., CDT – Conditioning High Percentages and 100% Outdoor Air • May 9, 12-1 p.m., CDT – Life Safety Dampers Warehouse Ventilation Strategies and Design Cons

  • Warehouse Design Overview

    1Overview of Warehouse Distribution Center DesignTypical Warehouse SystemsSummer VentilationSpace HeatingSmoke ExhaustCirculationSummer Ventilation3Summer VentilationExhaust fans and intake louvers are utilized to:Remove heat from the buildingReplace with fresh outdoor airProvide air movement throug

  • Amazon Project Overview 9-17-2021

    9/17/2021 Amazon Project Overview The information provided in this document is based on our experience with past Amazon projects and is intended to serve as a background information to aid in the bid process. Local code requirements may cause variations in design and the specifying engineer will det

  • std_steam_coils

    CAPACITY 12 Performance Data CFMEDBLDB DATENOTES 13 S 11 RF 1012 10 9 CUSTOMER 14 1 1/8 .010 .006 .020 16 GA. GALV. STEEL APPROVED BYTAG: MODEL NO. RETURN CU CASING L MAXCOAL HEADERS COPPER ONLY CONNECTION SIZES MPT 1 3/8 P.O. # W.O. # TUBES OD Wall Thickness COPPER ONLY FINS Material Thickness .016

  • New Test Standard for Dilution Blowers (CS/102-11)

    "® A technical bulletin for engineers, contractors and students in the air movement and control industry. Codes and Standards CS/102-11 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2011 Greenheck Fan Corp. New Test Standard for Dilution Blowers How AMCA Standard 2

  • Low Profile Modular Indoor Air-Handling Units (Model MSCF)

    "Product Specification GuideModel MSCF – Modular Small Cabinet FanSection 15700 – Modular Small Cabinet Fan Units ************************************************************************************************************************Note to User: This document is subject to copyright protection and

  • IG / IGX (#464104 IOM) (Pre-2009)

    "Part # 464104 ® MODELS IG / IGX Make-Up Air Unit Installation, Operation and Maintenance Manual Indirect Gas Fired Unit Installations Units are listed for installation in the United States and Canada • Installation of gas fired duct furnaces must conform with local building codes. In the absence of

  • CAD-10, HAD-10

    Greenheck duct access doors provide a durable, practical and inexpensive means of gaining access to components inside the ductwork. Recommended for use in low to medium pressure duct systems. HAD-10 CAD-10 access doors are rated for up to 41/2 in. (1.1 kPa) static pressure when properly installed. C

  • Application and Design ESU-154S is a frameless ultra thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into thru-wall air conditioning units. Standard

  • Duct Heaters Series: IDHB and IDHE (#478052 IOM)

    "Installation Supplements Refer to the appropriate Greenheck installation supplements for special requirements (www.greenheck.com links are underline): • IDHE-O Outdoor Applications • T725 Thermostat Installation Instructions • T725 Thermostat Operation Instructions • T855 Thermostat Installation In

  • RBD-10 Series

    " P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel Remote Balancing Dampers – RBD-10 SeriesFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ***************************************************************************************

  • Replacing the Fusible Link on Model DFDTF-210 (#468738 IOM)

    Document number 468738 Replacing Fusible Link on DFDTF-210 Refer to: ‘Installation Instructions for FSD-XXX, DFD-XXX, DFDTFXXX, SSFSD-XXX (Part no. 481318) These instructions are provided for changing fusible links on DFDTF-210. 1. Damper in the open position with fusible link attached 2. Damper in

  • Vari-Green Motor

    "Product Specification GuideVari-Green Control – EC Motor Motor to be an electronic commutation (EC) motor specifically designed for fan applications.AC induction type motors are not acceptable. Examples of unacceptable motors are: Shaded Pole, Permanent Split Capacitor (PSC), Split Phase, Capacitor