Search Results

Number of Results: 1441

Previous 23 24 25 26 27 Next Page 25 of 29
Results per page:
  • water_coils_

    Performance Data CFMEDB/EWBLDB/LWB 13 EWTLWTGPM S CAPACITY 12 1012 10 9 CUSTOMER 14 1 1/8 .010 .006 .020 16 GA. GALV. STEEL 11 DATENOTES APPROVED BYTAG: RFRETURN CU MODEL NO. CASING L MAXCOAL HEADERS COPPER ONLY CONNECTION SIZES MPT CDE P.O. # W.O. # TUBES OD Wall Thickness COPPER ONLY FINS Material

  • DX Coils Intertwined - Replacement blank coil drawings

    OAL CL FPISP1 MODEL NO. REFRIGERANT FHSP2MAX CH ROWS DX COILS INTERTWINED 2 1/8 RETURN F 12 8 6 534 ROWS AVAILABLE 678 FPI AVAILABLE 16 GA. STAINLESS STEEL .025 .035 ALUM. .016 .049 .006 5/8 1/2 16 GA. GALV. STEEL 9 .020 CASING HEADERS COPPER ONLY TUBES OD Wall Thickness COPPER ONLY FINS Material Th

  • MaxMod.valve_broch1

  • Specialty Shapes

    "Standard Construction Frame: Heavy gauge 6063T5 extruded aluminum Blades: Heavy gauge 6063T5 extruded aluminum positioned at 45° angles Birdscreen: 3⁄4"" x .051"" flattened expanded aluminum. Screen is mounted on inside (rear) Finish: Mill Minimum Size: 20"" Diameter. Consult Greenheck if smaller s

  • FPB Direct Drive

    "Product Specification GuideRadial Blade Pressure Blower, Direct Drive, Model FPBFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product spec

  • TCB w UL-762, Belt Drive

    "Product Specification GuideModel TCB-UL762 Commercial Tubular Centrifugal FanFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specifi

  • HPA Performance Supplement

    Plenum Fans Model HPA Performance Supplement October 2012 2 ® HPA Housed Plenum Fan HPA - 18 - 95 - S - B75 Wheel Size 15-36 Wheel Width 50-100 Model Housed Plenum Array Motor RPMs A = 1770 B = 1170 M = 3500 Housing Size C = Compact S = Standard (Default) L = Large 150 = 15 200 = 20 250 = 25 300 = 3

  • Vektor-CD Windband to Nozzle Fastener Kit (#1016014 IOM)

    1 Fastener Kit • Windband to Nozzle, Rev. 1, February 2018 Copyright 2018 © Greenheck Fan Corp. ® Document 1016014 Vektor-CD Fastener Kit Windband to Nozzle Laboratory Exhaust System Assembly Instructions READ THROUGH THESE INSTRUCTIONS PRIOR TO STARTING ASSEMBLY. Phone: (715) 359-6171 • Fax: (715)

  • QD-Cat_EnergyRecoveryVentilators

    62 Energy Recovery Ventilators Model ERV The ERV is designed for indoor and outdoor mounted applications requiring 500 to 12,000 cfm of ventilation air. A key design consideration for these units is mounting location. Several duct configurations allow for floor-mounted or ceiling-hung installation. Ac

  • 7800 Series Installation Instructions

    ® U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • All Rights Reserved INSTALLATION INSTRUCTIONS 66-1090-2 RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D 7800 SERIES Relay Modules APPLICATION The RM7895A,B,C,D/EC7895A,C; RM7896A,B,C,D are microprocessor-based integrated burner controls for automa

  • SP with CRD Damper with Plaster Flange Assembly (#481307 IOM)

    ® Document 481307 SP Fan with CRD Plaster Flange Assembly Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by obse

  • Vari-Green Control - Remote Dial

    "Product Specification GuideVari-Green Control – Remote Dial Remote Dial shall be a Vari-Green control specifically designed to provide 0-10 volt DC signal to Greenheck’s Vari-Green Motor. "

  • KSFB / KSFD (#463556 IOM)

    "® DB3 DBC Only qualified personnel should install this unit. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well a

  • Model AFL-501 Interior Cantilevered (IOM #483330)

    ® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with the

  • 120V to 24V Transformer

    24 Volt Secondary 120V Black 120 Volt Primary Capacity (VA) Primary Voltage Frequency (Hz) Secondary Voltage 60 120 50/60 24 The 120V to 24V transformer is used for converting primary voltage of 120 to secondary voltage of 24V. This transformer is shipped loose and is provided with a plate on the pr

  • Vektor-H Performance

    April 2017 Laboratory Exhaust Systems Vektor®-H Performance High Plume 2 Laboratory Exhaust Systems Model Vektor®-H Table of Contents Vektor-H Specification Chart ..........................................3 Plume Height Calculation.............................................3 Quick Select Chart ...

  • Model APEX

    August 2004 Energy Recovery Ventilator Model APEX •Heating and Cooling Options •10,000 to 20,000 cfm •Up to 2.5 in. wg external static pressure 2 Standard Construction With every APEX, you automatically receive: ✓ Blowers Motor Assemblies mounted on bases with vibration isolators for smooth, quiet o

  • SSFDR-510

    Installation instructions available at www.greenheck.com. Copyright © 2021 Greenheck Corporation SSFDR-510 Rev. 14 September 2021 SSFDR-510 Static Rated Round Fire Damper 11⁄2 Hour Fire Resistance RatingApplication Model SSFDR-510 is a round static rated fire damper for use in HVAC systems that are

  • Measuring Belt Tension This article discusses several methods for measuring the belt tension for V-belts commonly used in HVAC applications. Tensioning the belt is often done during initial startup and periodically throughout its life for preventative maintenance. Common belt tensioning methods are

  • DS-3 Air Velocity Selection Guide

    Air Velocity Selection Guide MODEL DS-3 HVLS Fans Greenheck HVLS Fans – Industry’s Coolest Fans. Literally. Effective air movement is critical to the performance of buildings and its occupants. With the ability to efficiently circulate large volumes of air, HVLS fans are an ideal solution for provid

  • RDC-8 Duct Conversion (#453380 IOM)

    1453380 • RDC-8 Duct Conversion, Rev. 3, September 2008 Copyright 2008 © Greenheck Fan Corp Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Report any damaged equipment to the shipper immediately. Read carefully before attempting to assemb

  • Understanding Fan Efficiency Grades (FEG) (CS/104-13)

    ® A technical bulletin for engineers, contractors and students in the air movement and control industry. P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2013 Greenheck Fan Corp. Codes Standards CS/104-13 Understanding Fan Efficiency Grades (FEG) Government agencies a

  • "EAH-401 (4"" Frame, Drainable Head)"

    Application and Design EAH-401 is an adjustable louver designed to protect air intake and exhaust openings in building exterior walls. Design incorporates a drainable head member, adjustable J style blades and high free area to provide maximum resistance to rain while providing minimum resistance to

  • External to Internal Mount for FSD and SMD Series (#481950 IOM)

    ® Mounting Kit for External to Internal 1® Document Number 481950 Mounting Kit for External to Internal Mount on Combination Fire Smoke Smoke Dampers (FSD and SMD Series) Tools needed: Phillips screwdriver Flat screwdriver Allen wrench Pliers 5⁄16, 3⁄8, and 7⁄16 inch sockets Socket driver There are

  • Belt Drive, Model RSFP

    "Product Specification GuideModel RSFP Belt Driven Double Width Centrifugal Louvered Penthouse Roof SupplyFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes:

  • Model RJ-4 (Pitched Roof Cap IOM)

  • Model ERV

    "Product Specification GuideGreenheck Model ERV –– Energy Wheel Air-to-Air Energy Recovery VentilatorFor Outdoor or Indoor InstallationCSI MasterFormat Category 23 XX XX (Greenheck suggests the use of category 23 72 13) ********************************************************************************

  • MSF (#482393 IOM)

    ® Direct Drive Supply Fan 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

  • Microprocessor Controller (#474706 IOM) TAP v1.04 June 2011 (ERCH, ERH, APEX, VER, ERT)

    "1DDC Controller for Tempered Air Products Reference Guide for the DDC Controller Please read and save these instructions. Read carefully before attempting to operate or maintain the product described. Protect yourself and others by observing all safety practices. Failure to comply with instructions

  • "AFS-120 (12"" Frame, Sightproof Blade)"

    AFS-120 Acoustical Louver, Sightproof Blade Formed Aluminum Standard Construction Frame Heavy gauge formed aluminum, 12 in. (305 mm) x 0.080 in. (2 mm) nominal wall thickness Blades Sightproof style, heavy gauge formed aluminum, 0.080 in. (2 mm) nominal wall thickness, positioned 45º on approximatel

  • Life Safety Dampers - An Integral Part of Effective Compartmentation… and the IBC

    Copyright ©2008 Greenheck Fan Corp. Page 1 Life Safety Dampers— An Integral Part of Effective Compartmentation… and the IBC Even when dampers are not required per the IBC due to the inclusion of sprinklers, it’s advisable to add them for critical smoke control and enhanced overall protection. The In

  • Warranty Statement for Class I Anodize

    P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Louvers Architectural Finish Limited Warranty Class I Anodize (215-R1 Clear, Champagne, Light Bronze, Medium Bronze, Dark Bronze, Extra Dark Bronze or Black Anodize) Greenheck warrants the finish of Class I

  • Damper Maintenance

    Damper Maintenance Greenheck’s dampers are designed to be trouble free and hassle free under normal operation. Dampers are to be installed square and straight so as to prevent binding during operation. The following annual damper maintenance suggestions will help to insure proper damper operation an

  • "FAD-402 (4"" Frame, Drainable Adjustable)"

    FAD-402 Adjustable Louver, Drainable Blade Fabricated Steel Standard Construction Frame 4 in. (102 mm) x 16 gauge galvanized steel wall thickness Blades Drainable design, 16 gauge galvanized steel wall thickness, positioned at 45º on approximately 4 in. (102 mm) centers Seals Dual-durometer extruded

  • Furnace Controller IGF v1.00 (#481155 IOM)

    ® Document 481155 Furnace Controller for Tempered Air Products Reference Guide for Furnace Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observi

  • McKnightCullinaire

    Greenheck Project Profile McKnight Cullinaire Catering Company Houston, TX Engineering Firm: Syska Hennessy Group, Inc. Houston, TX General Contractor: CAM Construction Houston, TX Mechanical Contractor: New Balance Houston, TX Greenheck Representative: HD Grant Houston, TX Ensure lower heating and

  • Campus_Map

    Greenheck Facilities - Schofield Mosinee, Wisconsin 4545 Alderson St., Schofield National Distribution Center • Finished goods warehouse, ceiling inline cabinet fans, roof curbs • 125,000 square feet • Opened in 1995 1110 Greenheck Dr., Schofield The Robert C. Greenheck Innovation Center • Research

  • TSU (#464441 IOM) (Pre-10/2017)

    ® Document 464441 Model TSU Make-Up Air Unit Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all saf

  • Furnace Controller v1.03 (#483843 IOM) March 2019

    ® Document 483843 Furnace Controller Reference Guide for Furnace Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

  • Warranty Statement for Gravity Ventilators FGI-FGR, GRSI-GRSR, WIH-WRH and RGU

    Gravity Ventilators (Models FGI, FGR, GRSI, GRSR, WIH WRH) Warranty Statement (12/12) Page 1 of 1 Copyright © 2012 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Gravity Ventilators – FGI/FGR, GRSI/GRSR, WIH/WRH and RGU Greenhe

  • SGA24 Potentiometer (#481675 IOM)

    Document number 481675 Belimo SGA Potentiometer Installation Instructions The Belimo SGA24 potentiometer can be field mounted to Greenheck FSD or SMD series damper supplied with Belimo FSAF24-SR(-S) acutators to allow the damper to be used to balance airflow in ducts. ® Note: Make sure that the slid

  • Model AX Pitch Protractor (Print at 100% on 8.5 x 11 Paper)

    0º 5º 10º 15º 20º 25º 30º 35º ALIGN THIS EDGE PARALLEL TO FAN CASING EDGE ALIGN THIS EDGE TO FAN CASING AXIAL LINE ® Instructions: • Follow Blade Pitch Adjustment Procedure as outlined in the AX High Performance Axial Installation, Operating and Maintenance Manual, Document #464664. • Align protract

  • MAC Ceiling Mount Kit (#474906 IOM)

    ® MAC Ceiling Mount Kit 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. F

  • What Sets Us Apart

    Designing your commercial kitchen ventilation project may seem complex. However Greenheck and our factory trained kitchen ventilation experts remove the complexity by providing engineering assistance, meeting codes and delivering reliable, quality components and systems on time. Our system approach

  • Model ERCH

    Energy Recovery with Cooling and Heating Model ERCH • 100% Outdoor Air System • Dedicated Outdoor Air System November 2021 • 1,000 - 10,000 cfm • 1.75 in. wg External Static Pressure • Indirect Gas, Hot Water, Electric Heating, Water-Source Heat Pump • Chilled Water, Split DX Cooling, Evaporative Co

  • Model ECV

    "Product Specification GuideGreenheck Model ECV ––Air-to-Air Energy Core VentilatorFor Outdoor or Indoor InstallationCSI MasterFormat Category 23 XX (Greenheck suggests the use of category 23 72 13) ****************************************************************************************************N

  • "GCI-402 (4"" Frame, Gravity Intake Damper)"

    GCI-402 Combination Intake Louver/Backdraft Damper, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Louver blade: J style design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nomin

  • Vari-Green Drive Model 100+ (#481200 IOM)

    "® Document 481200 VGD-100+ Vari-Green® Drive Vari-Green Drive 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

  • HPAC_Basic Fan Selection

    S By MOLLY REHWALDT and TIM MATHSON Greenheck Fan Corp. Schofield, Wis. Selecting a fan can be fairly complex. This article outlines the basic process for matching a fan to a system: 1) Define the application. 2) Select the basic fan. 3) Determine fan size and operating-point location. 4) Identify m

  • Flexible Kitchen Ventilation

    Copyright ©2008 Greenheck Fan Corp. Page 1 Flexible Kitchen Ventilation Contrary to popular belief, product choices do exist that enable us to achieve different levels of flexibility in our kitchen ventilation systems. As the title of this article spells out, I am going to write about flexible kitch

Previous 23 24 25 26 27 Next Page 25 of 29