  • EM-10 Series

    *W H dimensions furnished approximately 1⁄4 in.(6mm) under size. 3 1/8 in. Airflow 1 1/2 in. 1 1/2 in. 3 in. 5 in. 11 1 8 in. /EM-10 No Flange EM-11 Flange On Discharge EM-12 Flange On IntakeW x H Minimum Size Maximum Single Section Size Maximum Multi Section Size Inches 8 x 11 48 x 74 144 x 148 mm

  • An Analysis of Induced Flow Laboratory Exhaust Fan Systems and the Benefit of AMCA 260 Certified Performance FA/128-12

    A technical bulletin for engineers, contractors and students in the air movement and control industry P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • greenheck.com • Copyright © 2023 Greenheck Fan Corp. Fan Application FA/128-24 An Analysis of Induced Flow Laboratory Exhaust Fan Systems and the

  • Grease Hood Options - Wall Canopy

    August 2020 Grease Hoods – Type I Wall Canopy Hood Options and Accessories External Supply Plenum - Greenheck offers several arrangements to supply air back into the kitchen space uniformly. External plenums positioned at or near the exhaust hoods are the best alternative to integral supply plenums.

  • Linear Slot Diffuser Cross Reference Guide

    "Rev 1, March 2023 ■ Greenheck Fan Corp. ■ For complete product specifications and submittal data, visit us at greenheck.com Linear Slot Diffuser Competitor Cross Reference Guide Base Model Cross Reference Greenheck Model Slot Width Price Titus Krueger Nailor XG-6650 1/2"" SDS50 ML-37 1950 5050 XG-6

  • B2 Transitions for ODFD & OFD

    B2 Transitions for Out of Wall Fire Dampers Copyright © 2022 Greenheck Fan Corporation B2 Transitions for ODFD OFD, R1, January 2022 Greenheck Fan Corporation reserves the right to make product changes without notice. B2 Transitions for Out of Wall Fire Dampers (ODFD OFD)

  • RBD Actuator Kit (#473343 IOM)

    Document 473343 Actuator Kit RBD-10 As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specific product page or in the literature section of the website

  • Model GCC Metal Building Curb (#484905 IOM)

    Metal Building Curb 1 Document 484905 Model GCC Metal Building Curb Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and othe

  • Adjustable Roof Curbs (#483836 IOM)

    Dimensions in Inches Fits Fan Models 12 inch High Curb Outside Sq. Dim. Inside Sq. Dim. Weight Lbs. GPIA- 23.5-32G12-G 231⁄2 – 32 191⁄2 – 28 58 RE-20, RBE-20, RCE3-20, RBCE-20, RBS-20, RCS3-20, RBCS-20, RBF-20, RBCF-20, RDU-20, RBU-20, RBUMO-20 GPIA- 32.5-41G12-G 321⁄2 – 41 281⁄2 – 37 74 RE-24, RBE-

  • Remote Condensing Unit (#913836 IOM)

    "® Document 913836 Model RC Remote Condenser Remote Condenser 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

  • SP-80-VG and SP-110-VG with Energy Star Rating

    New Ceiling Exhaust Fans SP-80 and SP-110, with the ENERGY STAR® Most Efficient rating are now available. • Available with or without lights • Powered by electronically commutated (EC) motors • Performance range from 30-110 cfm and up to .6 in. wg. • Low sound levels for virtually silent operation.

  • Model ERT

    "Product Specification GuideGreenheck Model ERT –– Packaged Air-to-Air Energy Recovery Units with Cooling and/or HeatingFor Outdoor or Indoor InstallationCSI MasterFormat Category 23 XX XX(Greenheck suggests the use of category # 23 72 23) ************************************************************

  • Model ECV (#480955 IOM)

    "® Document 480955 Model ECV Energy Core Ventilator Energy Core Ventilator 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yoursel

  • CAPS Brochure

    eCAPS® CAPS Software eCAPS CAPS COMPUTER-AIDED PRODUCT SELECTION AND DESIGN SOFTWARE Two Great Tools to Guide You from Initial Design through Detailed Submittals • Increase your firm’s efficiency and accuracy when selecting air movement, control and conditioning products • Easy to use/No cost • Wide

  • Model GRRS

    March 2020 Fire Ready Residential Range Hood Model GRRS 2 Safety in Seconds Fire safety in kitchens is a necessity. Relying on portable fire extinguishers should never be the first step in your fire safety protocol when cooking. The best way to ensure fire safety in the kitchen is through deliberate

  • "ESD-635 (6"" Frame, Drainable Blade)"

    ESD-635 Stationary Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned

  • Vektor-ERS M Series

    "P.O. Box 410Schofield, WI 54476Phone: 715.359.6171www.greenheck.comProduct Specification GuideAddendum Specification, Model Vektor-MD, MH or MS, Vektor Energy Recovery SystemFacility Service Subgroup: Division 23 HVAC (previously Division 15) ********************************************************

  • Vertical Fan Coil Units (Model VFC)

    "Product Specification GuideModel VFC – Section 15700 - Vertical Fan Coil Units ************************************************************************************************************************Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan C

  • Variable Volume Laboratory Systems, an Overview (FA/124-05)

    FA/124-05 Variable Volume Laboratory Systems, an Overview On a variable volume laboratory exhaust system, hazardous and/or noxious contaminated air is exhausted through fume hoods, as well as through general exhaust grille(s), using a laboratory exhaust fan system. One of the goals of the exhaust fa

  • RDC-8 Duct Conversion (#453380 IOM)

    1453380 • RDC-8 Duct Conversion, Rev. 3, September 2008 Copyright 2008 © Greenheck Fan Corp Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Report any damaged equipment to the shipper immediately. Read carefully before attempting to assemb

  • Models DG, DGX, TSU and VSU Direct Gas-Fired Make-Up Air

    Direct Gas-Fired Make-Up Air Models DG, DGX, TSU and VSU Industrial, Manufacturing, Warehouse and Kitchen Applications May 2024 2 Models DG and DGX Setting the Industry Standard for Make-Up Air Model DG • 800 to 6,900 cfm and up to 3 in. wg • Cost-effective unitary housing construction for budget-se

  • HBTR Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification Guide – Model HBTR-151, HBTR-451, HBTR-551Model Bubble Tight DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) **********************************************************************

  • Motor Starters

    Greenheck Motor Starters Models MS-1P, MSAC, and MSEM Motor Protection April 2024 2 2 Greenheck Motor Starters Communication Challenges Communication breakdowns between the mechanical and electrical trades often lead to challenges with motor starters. Examples: • Mismatch between the starter and fan

  • Model PVe (#472846 IOM)

    1 Model PVe Heat Recovery Unit ® Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to compl

  • Model Vektor-ERS

    Energy Recovery Laboratory Exhaust Model Vektor®-ERS For Vektor-C and Vektor-M Series May 2024 2 Greenheck’s Vektor-ERS is a pre-engineered laboratory exhaust energy recovery system. In combination with our Vektor-C or Vektor-M series blowers, this system effectively removes contaminated laboratory

  • Understanding the Differences Between Backdraft and Relief Dampers – Application and Selection

    A successful HVAC system installation requires the correct components. Selecting most components is pretty simple. However, some can create problems. Backdraft and relief dampers, because of subtle differences and uses, can fall into that category. (Figure 1) Figure 1 Backdraft dampers, also known a

  • SEBR-10 Series

    "The SEBR-10 series is an eccentrically pivoted backdraft damper for low velocity systems. SEBR-10 series is a horizontally mounted damper and designed to allow vertical airflow up and prevent reverse airflow. On-blade counterweights are provided to fine tune start-to-open and full open blade operat

  • APEX Curbs (#462831 IOM)

    "STEP 1: Unpack and Inspect Parts Tools Recommended for Assembly • Cordless drill • 5/16 in. Nut setter • 9/16 in. Nut setter • Open or Closed 9/16 in. wrench • Awl — for hole alignment PART # 462831 April 2007 ® Roof Curb and Duct Adapter Model: APEX-200 ASSEMbly InSTRUCTIonS Part Description Qty P

  • Belt Drive, Model RBU

    "Product Specification GuideModel RBU Belt Drive Propeller Upblast FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes: This product specification guide is

  • HB-240

    Advise air flow direction counterbalance weight location when ordering * Actual inside dimension. *** RH counterbalance is standard. **** Counterbalance weights extend beyond inlet flange in the open position. LH RH Spark B C Resistant (Standard) Spark A Resistant (Optional)* Standard Optional Stand

  • RDC-6 Duct Conversion (#466215 IOM)

    Assembly and Installation Instructions Please read these instructions carefully before attempting to assemble the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result in personal injury and/or property damage! PN 466215

  • HVAC Coils IOM

    " P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Installation, Operation Maintenance Manual Water Coils • Chilled Water • Hot Water Steam Coils • Standard Steam • Steam Distribution (Non-Freeze) Refrigerant Coils • Condenser Coils • DX Coils (Evaporator) • Heat Reclaim Mainte

  • Microprocessor Controller for Energy Recovery Ventilators (#485131)

    ® Document 485131 Microprocessor Controller for Energy Recovery Ventilators Microprocessor Controller for ERV 1® Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

  • Microprocessor Controller for Energy Recovery Ventilators (IOM #484118)

    ® Document 484118 Microprocessor Controller for Energy Recovery Ventilators Microprocessor Controller for ERV 1® Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the

  • Hooded Propeller Roof Fans (Model RE2/RS2/RCE3/RCS3/RBE/RBS/RBCE/RBCS/RBF/RBCF/RPDR/RPBR/RPDRF/RPBRF)

    Hooded Roof Propeller Fans Belt and Direct Drive Exhaust, Supply and Reversible February 2024 2 Greenheck Fan Corporation certifies that the RE2, RCE3, RS2, RCS3, RBE, RBCE, RBS, RBCS, RBF and RBCF models shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and proce

  • Direct Drive, Model CSP-A

    "Product Specification GuideModel CSP-A Direct Drive Premium Inline Cabinet Centrifugal Exhaust FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes: This p

  • TBI-CA Belt Drive

    "Product Specification GuideModel Tube Axial Inline Belt Drive FansFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specification guid

  • SEBR-30Series

    SEBR-30 Series Barometric Relief Dampers Vertical Mount - Horizontal Airflow Application SEBR-30 Series May 2022 The SEBR-30 series is an eccentrically pivoted backdraft damper for low velocity systems. SEBR-30 series is a vertical mounted damper and designed to allow horizontal airflow and prevent

  • HBT-221

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification Guide – Model HBT-221 and HBT-321Model Bubble Tight DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) *******************************************************************************

  • HCD-240

    Model HCD-240 is a heavy duty industrial control damper with a flanged frame. It is designed to control airflow and provide shut off in HVAC or industrial process control systems. A variety of optional features makes model HCD-240 extremely versatile, allowing its capabilities to be tailored to the

  • "ESJ-155 (1 1/2"" Frame, J Blade)"

    Application and Design ESJ-155 is a thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into curtainwalls, windows, or as air conditioning grilles. Stand

  • Microprocessor Controller DOAS v3.001 (#483586 IOM) December 2018

    "® Document 483586 Microprocessor Controller for Dedicated Outdoor Air System Microprocessor Controller for DOAS 1® Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain t

  • Model CW/CWB (#457691 IOM)

    ® Document 457691 Model CW Direct Drive Model CWB Belt Drive Centrifugal Sidewall Exhaust Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Pro

  • Microprocessor Controller v3.0 (#469690 IOM)

    ® PART #469690 DDC CONTROLLER for ENERGY RECOVERY Installation, Operation and Maintenance Manual READ AND SAVE THESE INSTRUCTIONS MANEUVERING THROUGH THE CONTROLLER The DDC controller is located in the control panel on the energy recovery unit. The face of the DDC controller has six buttons allowing

  • "ESU-153S (1 1/8"" Depth, Frameless, 30 Degree Blade)"

    Application and Design ESU-153S is a frameless ultra thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into thru-wall air conditioning units. Standard

  • Greenheck Redesigns USF Centrifugal Utility Sets

    Greenheck has redesigned model USF single-width centrifugal utility sets in sizes 4 to 24 to incorporate more features and options. The USF now offers expanded direct drive selections with Vari-Green® motors up to 10 hp. Factory- mounted or ship-loose controls with VFDs are now available with belt o

  • Air Terminal Units – The Basics

    Ever think to yourself, how come I can adjust the temperature in the conference room without affecting my office? The answer is air terminal units (ATUs)! Why use ATUs? ATUs, also referred to as VAV boxes, allow occupants in a specific zone to adjust the temperature to their comfort level by regulat

  • "AFA-801 (8"" Frame, Airfoil Blade)"

    AFA-801 Acoustical Louver, Airfoil Blade Formed Aluminum Standard Construction Frame Heavy gauge formed aluminum, 8 in. (203 mm) x 0.080 in. (2 mm) nominal wall thickness Blades Airfoil style, heavy gauge formed aluminum, 0.080 in. (2 mm) nominal wall thickness, positioned 45º on approximately 6 in.

  • HPR-120

    RH LH Actual Inside Dimension. ** RH counterbalance and pressure settings are standard. *** Counterbalance and pressure setting weights extend beyond flanges in the open/closed positions. Model HPR-120 is a heavy duty pressure relief damper with double flanged channel frame and single thickness blad

  • Model USF (#479870 IOM)

    ® Universal Single Width Fans 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety informat

  • Model ESRMD/ERD (#453668 IOM)

    Only qualified personnel should install this fan. Personnel should have a clear understanding of these instructions and should be aware of general safety precautions. Improper installation can result in electric shock, possible injury due to coming in contact with moving parts, as well as other pote