Search Results

Number of Results: 1590

Previous 13 14 15 16 17 Next Page 15 of 32
Results per page:
  • Vektor-CD Arr 4 Direct Drive

    "P.O. Box 410Schofield, WI 54476Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel Vektor-CD Direct Drive High Plume Dilution BlowerFacility Service Subgroup: Division 23 HVAC (previously Division 15) *********************************************************************************

  • Vektor-CD Belt Drive

    "P.O. Box 410Schofield, WI 54476Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel Vektor-CD Belt Drive High Plume Dilution BlowerFacility Service Subgroup: Division 23 HVAC (previously Division 15) ***********************************************************************************

  • Vektor-MS Belt Drive

    "P.O. Box 410Schofield, WI 54476Phone: 715.359.6171www.greenheck.comProduct Specification GuideBelt Drive High Plume Blower, Model Vektor-MSFacility Service Subgroup: Division 23 HVAC (previously Division 15) *******************************************************************************************

  • Belt Drive, Model RBF-2

    "Product Specification GuideModel RBF-2 Belt Drive Hooded Roof Propeller Filtered Supply FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation auth

  • Belt Drive, Model RBF-1

    "Product Specification GuideModel RBF-1 Belt Drive Hooded Roof Propeller Filtered Supply FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation auth

  • Belt Drive, Model RBCF-3

    "Product Specification GuideModel RBCF-3 Belt Drive Hooded Roof Cast Aluminum Propeller Filtered Supply Fans Facility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan

  • Belt Drive, Model RB-3

    "Product Specification GuideModel RB-3 Belt Drive Hooded Roof Propeller FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a

  • Belt Drive, Model RB-2

    "Product Specification GuideModel RB-2 Belt Drive Hooded Roof Propeller FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a

  • Belt Drive, Model RB-1

    "Product Specification GuideModel RB-1 Belt Drive Hooded Roof Propeller FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a

  • "SED-501 (5"" Frame)"

    SED-501 Sightproof Louver, Chevron Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 5 in. (127 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Chevron design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned on

  • Belt Drive, Model RBF-3

    "Product Specification GuideModel RBF-3 Belt Drive Hooded Roof Propeller Filtered Supply Fan Facility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation aut

  • EVH-501

    EVH-501 Wind-Driven Rain Louver, Vertical Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 5 in. (127 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Vertical rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wall th

  • EVH-302

    EVH-302 AMCA 540 and 550 Listed Hurricane Louver Wind-Driven Rain Louver, Vertical Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6005-T5 aluminum, 3 in. (76 mm) x 0.081 in. (1 mm) jamb and 0.062 in. (2mm) head/sill nominal wall thickness Blades Vertical rain resistant desi

  • "ESK-402 (4"" Frame, K Blade)"

    ESK-402 Stationary Louver, K Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades K style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 37º and 45º on a

  • "ESJ-401 (4"" Frame, J Blade)"

    ESJ-401 Stationary Louver, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades J style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 37º and 45º on a

  • "ESJ-202 (2"" Frame, J Blade)"

    ESJ-202 Stationary Louver, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 2 in. (51 mm) x 0.063 in. (2 mm) nominal wall thickness Blades J style, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wall thickness, positioned 45º on approximat

  • ESD-635X

    ESD-635X AMCA 540* Listed Hurricane Louver Florida Product Approved Extruded Aluminum, Stationary Standard Construction Mounting Continuous aluminum angles along the head, sill, and jambs Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Dra

  • ESD-635PD

    Application and Design ESD-635PD is a gravity intake or exhaust louvered penthouse. Model ESD-635PD incorporates high performance horizontal drainable style blades. Meets the performance requirements established by the Florida Building Code and Miami-Dade County. Tested in accordance with and passes

  • ESD-635HP

    ESD-635HP Stationary Louver, Drainable Blade Extruded Aluminum ESD-635HP August 2023 Document Links Louver Finishes Colors Louver Product Selection Guide Louver Products Catalog Louver Warranty Statement Options and Accessories • Bird Screen • Blank Off Panels • Extended Sill • Filter Rack/Filter •

  • ESD-603

    ESD-603 Stationary Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.063 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wall thickness, positioned

  • ESD-435X

    ESD-435X AMCA 540* Listed Hurricane Louver Florida Product Approved Extruded Aluminum, Stationary Standard Construction Mounting Continuous aluminum angles along the head, sill, and jambs Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Dra

  • "ESD-202 (2"" Frame, Drainable Blade)"

    ESD-202 Stationary Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 2 in. (51 mm) x 0.063 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wall thickness, positioned

  • "ESD-403 (4"" Frame, Drainable Blade)"

    ESD-403 Stationary Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned

  • "ESD-435 (4"" Frame, Drainable Blade)"

    ESD-435 Stationary Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned

  • EHV-901

    EHV-901 AMCA 540 and 550 Listed Hurricane Louver Extruded Aluminum, Wind-Driven Rain Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 9 in. (229 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Front: J style design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nomin

  • Overhead Fan Controls – Standard Touchscreen

    "Product Specification GuideOverhead Fan Controls – Standard Touchscreen Control Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a limited non-exclusive license to use this document

  • Overhead Fan Controls – Keypad

    "Product Specification GuideOverhead Fan Controls – Keypad Control Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a limited non-exclusive license to use this document or portions o

  • Overhead Fan Controls – Advanced Touchscreen

    "Product Specification GuideOverhead Fan Controls – Advanced Touchscreen With BACnet® Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes the user a limited non-exclusive license to use this doc

  • DM-3 Direct Drive

    "PRODUCT SPECIFICATION GUIDEMODEL DM-3 (FAN SIZE 5, 60 IN. DIAMETERS), DIRECT DRIVE LOW SPEED, SMALL DIAMETER (LSSD) OVERHEAD FANS FACILITY SERVICES SUBGROUP: DIVISION 23 SECTION 23 34 39 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation.

  • DS-3, Direct Drive

    "Product Specification GuideModel DS-3, Direct Drive High Volume, Low Speed (HVLS) Overhead Fans Facility Services Subgroup: Division 23 Section 23 34 39 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation

  • DS-6, Direct Drive

    "Product Specification GuideModel DS-6, Direct Drive High Volume, Low Speed (HVLS) Overhead Fans Facility Services Subgroup: Division 23 Section 23 34 39 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation

  • "EHM-601 (6"" Frame, Dual Drainable Blade, Hidden Mullion)"

    EHM-601 Hidden Mullion Louver, Dual Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Dual drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickne

  • Model Vektor-ERS (#474118 IOM)

    ® Vektor-ERS Energy Recovery Plenum Laboratory Exhaust 1® Document 474118 Energy Recovery System (ERS) Laboratory Exhaust Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or mai

  • EHH-701

    EHH-701 Wind-Driven Rain Louver, Horizontal Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 7 in. (178 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Horizontal rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wal

  • EHH-601DE

    EHH-601DE AMCA 540 Listed Hurricane Louver Miami-Dade and Florida Product Approved Extruded Aluminum, Wind-Driven Rain EHH-601DE August 2023 Product Details EHH-601DE Standard Channel Frame Details EHH-601DE Optional Flange/Sleeve Frame Details Channel and Flange/Sleeve Installation (IOM #481315) Mi

  • "EHH-601 (6"" Frame, Horizontal Blade)"

    EHH-601 Wind-Driven Rain Louver, Horizontal Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Horizontal rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wal

  • EHH-501X

    EHH-501X August 2023 Product Details EHH-501X Standard Details EHH-501X (#475580 IOM) Structural reinforcing members may be required to adequately support and install multiple louver sections within a large opening. Structural reinforcing members along with any associated installation hardware is no

  • "EHH-201 (2"" Frame, Horizontal Blade)"

    EHH-201 Wind-Driven Rain Louver, Horizontal Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 2 in. (51 mm) x 0.063 in. (2 mm) nominal wall thickness Blades Horizontal rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wall

  • EHH-401

    EHH-401 Wind-Driven Rain Louver, Horizontal Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Horizontal rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2 mm) nominal wal

  • "EHH-501 (5"" Frame, Horizontal Blade)"

    EHH-501 Wind-Driven Rain Louver, Horizontal Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 5 in. (127 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Horizontal rain resistant design, heavy gauge extruded 6063-T5 aluminum, 0.063 in. (2mm) nominal wall

  • "EDK-430 (4"" Frame, 30 degree K Blade)"

    EDK-430 Stationary Louver, K Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades K style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 30º on approxima

  • "EDJ-601 (6"" Frame, J Blade)"

    EDJ-601 Stationary Louver, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.063 in. (2 mm) nominal wall thickness Blades J style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 37º and 45º on a

  • "EDJ-401 (4"" Frame, J Blade)"

    EDJ-401 Stationary Louver, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades J style, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 37º and 45º on a

  • "EDD-601 (6"" Frame, Dual Drainable Blade)"

    EDD-601 Stationary Louver, Dual Drainable Blade Extruded Aluminum EDD-601 August 2023 Document Links Louver Finishes Colors Louver Product Selection Guide Louver Products Catalog Louver Warranty Statement Options and Accessories • Bird Screen • Blank Off Panels • Extended Sill • Filter Rack/Filter •

  • "EDD-401 (4"" Frame, Dual Drainable Blade)"

    EDD-401 Stationary Louver, Dual Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Dual drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness,

  • Model AFL-501

    Greenheck Fan Corporation certifies that the AFL-501 louvers shown herein are licensed to bear the AMCA Seal. The ratings shown are based on tests and procedures performed in accordance with AMCA Publication 511 and comply with the requirements of the AMCA Certified Ratings Program. The AMCA Certifi

  • "AFJ-801 (8"" Frame, J-Blade)"

    AFJ-801 Acoustical Louver, J Blade Formed Aluminum Standard Construction Frame Heavy gauge formed aluminum, 8 in. (203 mm) x 0.080 in. (2 mm) nominal wall thickness Blades J style, heavy gauge formed aluminum, 0.080 in. (2 mm) nominal wall thickness, positioned 45º on approximately 5 in. (127 mm) ce

  • "AFJ-601 (6"" Frame, J-Blade)"

    AFJ-601 Acoustical Louver, J Blade Formed Aluminum Standard Construction Frame Heavy gauge formed aluminum, 6 in. (152 mm) x 0.080 in. (2 mm) nominal wall thickness Blades J style, heavy gauge formed aluminum, 0.080 in. (2 mm) nominal wall thickness, positioned 45º on approximately 5 in. (127 mm) ce

  • "AFJ-120 (12"" Frame, J-Blade)"

    AFJ-120 Acoustical Louver, J Blade Formed Aluminum Standard Construction Frame Heavy gauge formed aluminum, 12 in. (305 mm) x 0.080 in. (2 mm) nominal wall thickness Blades J style, heavy gauge formed aluminum, 0.080 in. (2 mm) nominal wall thickness, positioned 45º on approximately 5 in. (127 mm) c

  • eCAPS Bridge _Using Schedule Button

    For feedback or questions, contact: BIM@GREENHECK.COM GREENHECK eCAPS BRIDGE FOR REVIT Using the ‘Schedule’ Button • The ‘Schedule’ button allows users to create schedules for Fans, HVLS, Gravity, Louver or preconditioner products, based off Greenheck shared parameters in LOD 300 families present in

Previous 13 14 15 16 17 Next Page 15 of 32
Results per page: