Search Results

Number of Results: 1590

Previous 15 16 17 18 19 Next Page 17 of 32
Results per page:
  • Gravity Ventilator, Model GRSR

    "Product Specification GuideModel GRSR Spun Aluminum Relief Gravity VentilatorFacility Services Subgroup: Division 23 Section 23 37 23 ************************************************************************************************************************ Specifier Notes: This product specification

  • Belt Drive, Model USGF

    "Product Specification GuideModel USGF Belt Drive Roof Upblast Centrifugal Exhaust FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************* Specifier Notes: This product specification gui

  • Direct Drive, Model AE/AS

    "Product Specification GuideModel AE/AS Direct Drive Roof Downblast Propeller FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes: This product specificati

  • Belt Drive, Model GB

    "Product Specification GuideModel GB Belt Drive Roof Downblast Centrifugal Exhaust FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************* Specifier Notes: This product specification gui

  • Models APD, APM and APH Plenum Fans (#475405 IOM)

    ® Plenum Fans 1 Document 475405 Models APD, APH APM Plenum Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others b

  • Warranty Statement for Dedicated Outdoor Air Systems (DOAS)

    Dedicated Outdoor Air Systems (DOAS) Warranty Statement (5/2023) Page 1 of 1 Copyright © 2023 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Dedicated Outdoor Air Systems (DOAS) Unit Warranty Greenheck warrants the equipment to

  • HVAC Control & Balancing Dampers, Models VCD, MBD and RBD

    HVAC Control Balancing Dampers Models VCD, ICD, FBH, FBV, MBD and RBD • Selection • Construction • Performance May 2023 2 Frame Options There are five frame options available: • Channel (standard) - allows damper to be insert mounted into an opening or duct • Single flange or single reversed flange

  • Direct Drive, Model DDF

    "Product Specification GuideModel DDF Direct Drive Directional Destratification FanFacility Services Subgroup: Division 23 Section 23 34 23 Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation. However, Greenheck Fan Corporation authorizes th

  • Motor Warranty Claim Form

    Contact motorwarranty@greenheck.com with any questions. Revision 3.16.2023 Motor Warranty Claim Form Includes Vari-Green Motors Completed form must be returned within 30 days of order date to avoid charge-back Select Motor Failure: ☐ Burnt Out ☐ Bent/Seized motor shaft ☐ Broken wire inside motor ☐ D

  • HOA Controller (#485055 IOM)

    "[§.GREENHECK • Building Value in Air. Document 485055 100 ~ 277Vac HOA Controller User and Service Manual Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the produ

  • BTDR-50

    BTDR-50 Bowtie Damper Application BTDR-50 January 2023 Model BTDR-50 is a cable operated radial blade balancing damper (also known as bowtie damper) that is designed for easy airflow adjustment at an air outlet or plenum neck. This damper is ideal for applications where it is difficult to get access

  • BTDR-50 (#486079 IOM)

    ® BTDR Series 1® Document 486079 BTDR Series Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all saf

  • April_2023_class_descriptions

    HVAC University Course Descriptions Classes April 11: Life Safety Dampers April 17: Air-to-Air Energy Recovery April 18: Increasing Design Efficiency Using Software Life Safety Dampers Developed to provide basic information on life safety dampers, this course discusses fire, fire smoke, smoke, and c

  • VirtualHVACUemail_April_2023

    Sample email for you to send to your customersTo: From: Subject: Greenheck’s Virtual HVAC University Classes We are excited to inform you that Greenheck is offering virtual HVAC University classes. Several one-hour classes on different topics are presented monthly. The classes are presented live by

  • Model MiniVent (459023 IOM)

    "® Document 459023 Model MiniVent Energy Recovery Ventilator Energy Recovery Ventilator 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Pr

  • Model MiniCore (#479677 IOM)

    "1Energy Core Ventilator Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Fai

  • HCDR-351

    Size is actual inside dimension. Model HCDR-351 is a heavy duty round industrial isolation damper with a flanged style frame. It is designed to provide tight shutoff with very low leakage in HVAC or industrial process control systems. Standard Optional Frame Material Painted Steel 304SS, 316SS Frame

  • BVE (Extruded Aluminum)

    BVE Brick Vent Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.125 in. (3 mm) nominal wall thickness Blades Heavy gauge extruded 6063-T5 aluminum, 0.125 in. (3 mm) nominal wall thickness, positioned 45º Louver Depth 4 in. (102 mm) Construction

  • Model PLG Plug Fans (#1037585 IOM)

    ® Plug Fans 1 Document 1037585 Model PLG Plug Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing a

  • Model GJI

    GJI-26 GreenJet Mixed Flow Jet Fan Greenheck’s GJI low-profile mixed flow jet fan is designed for parking garage and air movement applications. Cars operating in an enclosed parking structure emit carbon monoxide (CO) and other noxious fumes into the atmosphere. An efficient ventilation system is ne

  • March_2023_class_descriptions

    HVAC University Course Descriptions Classes March 15: Conditioning High and 100% Outdoor Air March 16: HVLS Fan Design, Application, and Specification March 27: Ventilation Strategies Utilizing Ceiling Exhaust and Bathroom Exhaust Fans to Meet Indoor Air Quality Requirements Conditioning High Percen

  • Fume Exhaust and Vektor Laboratory Exhaust

     Indicates new or revised literature February 2023 Selection Guide for Fans Catalog: AMCA and Greenheck (00.LAB.1000 R3 10-2011 RG) FUME EXHAUST PRODUCTS  Catalog: FumeJet™ Exhaust Systems (00.LAB.1019 R4 4-2022 SP) Catalog: GreenJet® Transfer Fans (00.LAB.1020 R1 4-2018 RG) VEKTOR® LABORATORY EXH

  • HBT-321

    * Actual inside dimension. The W dimension is ALWAYS parallel with the damper blade length. Axles must always be in the horizontal plane. W x H Minimum Size Maximum Size 1 Blade 2 Blades Inches 6 x 6 48 x 14 48 x 251⁄2 mm 152 x 152 1219 x 356 1219 x 648 3 Blades 4 Blades Inches 48 x 39 48 x 42 mm 12

  • GJI

    "Product Specification GuideCommercial Mixed Flow Jet Fan, Model GJIFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specification gui

  • Model SP-AP

    SP-AP0511WL (lighted) Precision Ventilation Fan Models SP-AP0511W SP-AP0511WL January 2023 2 Exclusive Features: • MASTERSPEC™ SP-AP Series is powered by an electronically commutated motor (ECM) with Constant CFM adaptive, variable speed technology programmed to overcome the static pressure associat

  • February_2023_class_descriptions

    HVAC University Course Descriptions Classes February 21: Make-Up Air Ventilation February 22: Laboratory Fume Exhaust February 23: Motor Technology in the HVAC Industry Make-Up Air Ventilation This course discusses make-up air systems used in commercial kitchens and industrial applications. Topics i

  • Jump Over Bracket Kit (#482403 IOM)

    "These instructions address how to mount a jumpover bracket when you want to join two damper sections. Applicable to Models VCD-20, VCD-23, VCD-33, VCD-34, VCD-42, and VCD-43 Kit Number 879586: VCD-20 and VCD-23 The jumpover bracket can be used on dampers 10 inches or higher (under 10 inches the bla

  • VCD-40 Extension Pin Kit (#475289 IOM)

    For Dampers Installed in Ducts Extended control shaft is installed from outside of duct after damper is installed. Install as shown in this document. Tools Required 5⁄16 in. Hex Nut Drive 3⁄8 in. Electric Drill 1⁄2 in. Open End Wrench Extension Pin with Clip Part Number 846031 Extension Pin with Cli

  • Wind-Driven Rain Louvers - Vertical Blade (#486050)

    ® Vertical Blade, Wind-Driven Rain Louver Models 1® Document 486050 Vertical Blade, Wind-Driven Rain Louvers Models EVH-302 and EVH-501 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install,

  • Models RSF (#479826 IOM)

    "Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with inst

  • Combination Louver/Dampers - Models EAC and EACA (#486039)

    ® Operable, Combination Louver/Dampers 1® Document 486039 Operable, Combination Louver/Dampers Models EAC-401, EAC-601, and EACA-601 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, ope

  • ICD Installation Instructions (#468333 IOM)

    Receiving and Handling Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Damp

  • BR Series – Counterweight Adjustment (#469420 IOM)

    Receiving and Handling Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Damp

  • MP-100A (#463548 IOM)

    ® MP100A motorpack 1® Document 463548 MP-100A Motor Pack Electric actuators with spring return for use with WD-100 series dampers Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operat

  • MP-310 (#463547 IOM)

    "® Document 463547 MP-310 Motor Pack Electric actuators with spring return for use with WD-300 series dampers Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the pr

  • MP-210 (#463546 IOM)

    ® MP-210 motorpack 1® Document 463546 MP-210 Motor Pack Spring return electric actuators for use with WD-200 series damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or ma

  • MP-220A (#463544 IOM)

    ® Document 463544 MP-220A Motor Pack Spring return electric actuators for use with WD-200 series damper Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product

  • January_2023_class_descriptions

    HVAC University Course Descriptions Classes January 20: Proper Application and Specification of Ceiling Radiation Dampers and Ceiling Radiation Damper-Ceiling Exhaust Fan Combinations January 30: Warehouse Ventilation Strategies and Design Considerations January 31: Understanding AMCA 500-L Louver W

  • 2023 Scholarship Application

    Scholarship Application Name: Maiden Name: (if applicable) Home Address: Phone Number: PERSONAL Date: ELIGIBILITY First Middle Last Street City, State Zip Code Are you a child of an employee of Greenheck Group or one of its subsidiaries? Yes No Employee Name: First Middle Last Location Department Em

  • RRL2 Option

    Copyright © 2022 Greenheck Fan Corporation RRL2, R4, July 2022 Greenheck Fan Corporation reserves the right to make product changes without notice. RRL2 Resettable Link Option for CRD-501 Application The RRL2 replaces the fusible link on a CRD-501 damper with an electric sensor (thermostat). The sen

  • 2023 Scholarship Application Criteria/Instructions

    40th Annual Scholarship Program 1100 Greenheck Drive, PO Box 410, Schofield, WI 54476 715-359-6171 | greenheck.com The Greenheck Group is pleased to support the academic efforts of students with our scholarship program. This program is open to all children of Greenheck Group employees, except the ch

  • MBDR-50

    MBDR-50 Manual Balancing Damper Round Diameter Minimum Maximum in. (mm) 4 in. (102) 24 in. (610) Options and Accessories • 11⁄2 in. (38mm) stand off bracket (with extended pin) to accommodate for the thickness of external duct insulation • 2 in. (51mm) stand off bracket • Cable Operator • Round Ceil

  • ABD-FD

    Diameter (mm) Individual Set Points Airflow Range - CFM* (m3/s) 4 in (102) 20 25 to 130 (.012 to .061) 6 in (152) 24 50 to 275 (.024 to .130) Airflow Range by Size * Note: Airflow range determined through +/- 10% of average airflow over the pressure range. See complete marking on product. UL 2043 Cl

  • GFSD-211

    See complete marking on product. UL 555 and UL 555S Classification R13317 W x H Minimum Size Maximum Size Single Section MultipleSection Inches 14 x 12 42 x 48 48 x 48 mm 356 x 305 1067 x 1219 1219 x 1219 Model GFSD-211 is a combination fire smoke damper with 3V style blades designed for easy access

  • ESU-154

    Application and Design ESU-154 is a thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into curtainwalls, windows, or as air conditioning grilles. Stand

  • ESU-153

    "Application and Design ESU-153 is a thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into curtainwalls, windows, or as air conditioning grilles. Stan

  • December_2022_class_descriptions

    HVAC University Course Descriptions Classes  December 1: Life Safety Dampers  December 6: Air-to-Air Energy Recovery  December 20: Ventilation Strategies Utilizing Ceiling Exhaust and Bathroom Exhaust Fans to Meet Indoor Air Quality Requirements Life Safety Dampers Developed to provide basic info

  • Indoor Air Quality In Schools Is Necessary

  • Birdscreen Kit (#486001 IOM)

    Birdscreen Kit 1 Document 486001 Birdscreen Kit Centrifugal Upblast Exhaust Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself

  • Mitigating The Risk of COVID-19 and Improving Indoor Air Quality In Schools

Previous 15 16 17 18 19 Next Page 17 of 32
Results per page: