  • Models ERM 36 & 52 (#456785 IOM)

    ® Energy Recovery Modules 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information.

  • Model IGX

    "Product Specification GuideGreenheck Model IGX – Packaged Make-Up Air Unit with Indirect Gas-Fired Furnace and Optional Cooling For Outdoor or Indoor InstallationCSI MasterFormat Category 23 74 XX ******************************************************************************************************

  • PVF/PVG Indirect Gas-Fired Heat Modules (#474645 IOM) pre-August 2015

    ® Document 474645 Model PVF and PVG Indirect Gas-Fired Heat Modules Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and othe

  • Isolation Bypass Dampers & Controls

    Greenheck’s bypass air dampers and isolation dampers are designed to provide superior airflow control in severe environments. System dampers are designed and sized for specified application pressure and flow requirements. Both isolation and/or bypass air dampers on Vektor systems are available with

  • Model SP-L, Wall/Ceiling Exhaust Fan

    ® Document 481174 Model SP-L Wall/Ceiling Exhaust Fan Wall/Ceiling Exhaust Fan 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect you

  • KSFB / KSFD (#471553 IOM)

    Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instr

  • Industrial Damper Torque - How the Options You Select Affect Actuator Selection and Costs (DA/102-13)

    "® A technical bulletin for engineers, contractors and students in the air movement and control industry. P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2013 Greenheck Fan Corp. Damper Application DA/102-13 Industrial Damper Torque — How the Options You Select Affec

  • Temperature Interlock (#471738 IOM)

    Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instr

  • DFDR-500 and SSDFDR-500 Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel DFDR-500 AND SSDFDR-500 Series Round Dynamic DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ***************************************************************************

  • UL Marking and Application Guide - Dampers

    Dampers Marking and Application Guide UL and the UL logo are trademarks of UL LLC © 2014 1 Dampers Marking and Application Guide Dampers Marking and Application Guide UL and the UL logo are trademarks of UL LLC © 2014 2 PREFACE Fire and smoke protection - Building codes rely on fire and smoke protec

  • ABD-Z1

    " P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel Automatic Balancing Damper – ABD-Z1Facility Service Subgroup: Division 23 HVAC (Previously Division 15) ********************************************************************************************

  • Remote Condensing Unit (#913836 IOM)

    "® Document 913836 Model RC Remote Condenser Remote Condenser 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others

  • TCB TCBRU TCBRS Belt Drive

    "Product Specification GuideModel Commercial Tubular Centrifugal FansFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specification gu

  • Models WIH/WRH (IOM #481513)

    Document 481513 Model WIH/WRH ASSEMBLY INSTRUCTIONS Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with

  • QD-Cat_PackagedRooftopVentilation

    Packaged Rooftop Units Model RV and RVE The RV and RVE (with energy recovery) are pre-engineered rooftop ventilators specifically designed to condition and deliver mixtures of outdoor and return air to a building. Pre-engineered features provide semi-custom flexibility while maintaining the quality, c

  • Exhaust Weatherhood, Models ERV, ERH, ERCH and APEX (#462844 IOM)

    Unpack, inspect, and verify receipt of the correct weatherhood pieces for your unit. Some energy recovery units will require two exhaust weatherhoods. The exhaust weatherhood provided with your energy recovery unit is based on the exhaust blower model size. To determine the weatherhood you have rece

  • QD-Cat_AirCirculators

    20 Air Circulators Standard Construction Propeller - three-bladed, aluminum OSHA compliant polyester powder-coated wire guard Totally enclosed air over permanent split capacitor motor Factory-wired, 10 foot power cord with 3-conductor plug 2-speed pull chain switch - operation OFF-LOW-OFF-HIGH Ball

  • Model ERV (#455924 IOM) (Pre April 2013)

    "® 1Energy Recovery Ventilator® Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply

  • ABD-Z2

    " P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel Automatic Balancing Damper – ABD-Z2Facility Service Subgroup: Division 23 HVAC (Previously Division 15) ********************************************************************************************

  • Out of Wall Dynamic Fire Dampers Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel Out of Wall Dynamic Fire DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ***********************************************************************************************

  • CAD and HAD (Access Doors)

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel CAD and HAD Access DoorsFacility Service Subgroup: Division 08 Door and Window *************************************************************************************************************Note to

  • Indirect Gas-Fired Technical Guide

    "® Indirect Gas-Fired Technical Guide April 2012 2 TYPICAL SPECIFICATIONS H V CONTROLS MAKE-UP AIR CONTROLS FILTERS DIFFUSERS FURNACE VENTING MODEL IGX DATA MODEL IG DATA ® Table of Contents Model Name Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • 2019 Scholarship Application

    Scholarship Application Name: Maiden Name: (if applicable) Home Address: Phone Number: PERSONAL Date: ELIGIBILITY First, Middle, Last Street City/State/Zip Code Are you a child of an employee of Greenheck Group or one of its subsidiaries? Yes No Employee Name: First, Middle, Last Location Department

  • Midtown_Global_Project

    Greenheck Project Profile Midtown Global Market Minneapolis, MN Planning Consultant: HRI Consulting Falcon Heights, MN General Contractor: Ryan Construction Minneapolis, MN Design Build Contractor: Master Mechanical Eagan, MN Greenheck Representative: TMS Johnson, Inc. New Hope, MN Efficiently exhau

  • RBD-15

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel RBD-15 Balancing DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ****************************************************************************************************Not

  • VSU (#457831 IOM) (Pre-2012)

    "1 Model VSU Make-Up Air Unit Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply w

  • Model HRE - Heat Recovery Unit with Evaporative Cooling (#461248 IOM)

    "RECEIVING AND HANDLING The HRE is thoroughly inspected and test run at the factory. However, damage may occur during shipping and handling. Upon delivery, inspect the unit for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim

  • Vari-Green Control - Universal Assemblies (#475699 IOM)

    ® Document 475699 Universal Vari-Green® Control Assemblies Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by obs

  • Gravity Ventilator, Model FGR

    "Product Specification GuideModel FGR Fabra Hood Relief Gravity VentilatorFacility Services Subgroup: Division 23 Section 23 37 23 ************************************************************************************************************************ Specifier Notes: This product specification guid

  • LabCoat: Corrosion Resistant Coating

    LabCoat™ …a superior coating for superior fan endurance in laboratory exhaust applications Coating quality for corrosive exhausts based on coating thickness is a myth. A thicker coating (greater number of mils) is not necessarily better. Greenheck LabCoat Advantages: • Base material preparation (cle

  • Energy Recovery Technologies (ERA/115-15)

    ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Energy Recovery Application ERA/115-15 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2015 Greenheck Fan Corp. Energy Recovery Technologies Energy recovery is a

  • Out of Wall Static Curtain Style

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel Out of Wall Static Fire DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ************************************************************************************************

  • ABS Certificate of Design

  • Payback Analysis - Variable Volume Arrangement

  • QD-Cat_BathandInlineFans

    22 Bath and Inline Fans UL/cUL 507 - E33599 - Ceiling Exhaust Fans Model SP-A390 and smaller and SP-B are UL/cUL Listed for above bathtub/shower with GFCI branch protected circuit. Model SP-C is UL/cUL Listed SP UL/cUL 507 - Cabinet Fans - E33599 Model CSP-A and CSP-B are UL/cUL Listed. CSP Model Be

  • Industrial Heating Equipment Comparison and Evaluation (MUA/100-02)

    "product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Make-Up Air Application MUA/100-02 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2002 Greenheck Fan Corp. ® Industrial Heating Equipm

  • Warranty Statement for Kynar/Acroflur Finish (50% PVDF)

    P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Louvers Architectural Finish Limited Warranty Kynar/Acroflur (50% PVDF) Paint Greenheck warrants the finish of Kynar/Acroflur (50% PVDF) paint for a period of 5 years from the date of product shipment when applied to aluminum lou

  • No Flow Duct Smoke Detector (System Sensor)

    Agency Listings Duct Smoke Detector for Special Applications The System Sensor 2151 low-profile photoelectronic smoke detector is UL listed to UL 268A specifically for use in no-flow/low-flow air-handling systems. Features • Low-profile smoke detector design • Low standby current • Two LEDs blink in sta

  • MBD-10X Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel Manual Balancing Dampers – MBD-10Facility Service Subgroup: Division 23 HVAC (Previously Division 15) **********************************************************************************************

  • Using the ‘Reselect’ button

    For feedback or questions, contact: BIM@GREENHECK.COM GREENHECK eCAPS BRIDGE FOR REVIT Using the ‘Reselect’ button • The Reselect button allows users to rapidly make modifications to selected LOD300 families in the Revit project. • The Reselect button is deactivated by default and automatically acti

  • AMD-23, AMD-33, AMD-42

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel AMD-23, AMD-33, and AMD-42 Control dampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) *************************************************************************************

  • Vektor-M ERS Fastener Kit – Knock Down ERS Roof Curb (#1016916 IOM)

    "1 Fastener Kit • Knock Down ERS Roof Curb ® Document 1016916 Vektor-M ERS Fastener Kit Knock Down ERS Roof Curb Laboratory Exhaust System Assembly Instructions READ THROUGH THESE INSTRUCTIONS PRIOR TO STARTING ASSEMBLY. Assembly Instructions for Curb Panels and Brackets (Fastener Kits 915007 – 9150

  • HB-XX Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel HB-xx0 Series Backdraft DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) ************************************************************************************************

  • Model MPX with Packaged Cooling & Heating

    "October 2011 Make-Up Air with Packaged Cooling Heating Model MPX • Commercial • Industrial • Institutional • 100% Outdoor Air • 1,000 - 9,000 cfm • 3.0 in. wg external static pressure 2 Product Overview 100% Outdoor Air System with Packaged DX Cooling The thermal comfort of occupants in industrial,

  • "EACC-401 (4"" Frame, Concealed Actuator)"

    EACC-401 Combination Louver/Damper, Concealed Actuator Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) head/jamb and 6.2 in. (157 mm) sill x 0.125 in. (3 mm) nominal wall thickness Blades Stationary blade: drainable design, heavy gauge extruded 606

  • "EAC-401 (4"" Frame, Concealed Linkage)"

    EAC-401 Combination Louver/Damper, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.125 in. (3 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, po

  • Coil Dimension Guidelines

    " P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Coil Dimension Guidelines Rows • Horizontal rows of tubes in the fin pack • Chilled Water and DX Coils – 1 to 12 rows • Hot Water Coils – 1 to 12 rows • Steam Coils – 1 to 2 rows • Condenser Coils – 1 to 12 rows FPI – Fins Per

  • Installation instructions available at www.greenheck.com. Copyright © 2018 Greenheck Corporation PRV Rev. 9 November 2018 Pneumatic Relief Valve (PRV) Pneumatic Temperature Response Device Application The Pneumatic Relief Valve (PRV) is a heat responsive device used in conjunction with Greenheck’s c

  • Istinye Park_Turkey

    Greenheck Project Profile Istinye Park Shopping Mall Istinye, Sariyer, Istanbul, Turkey Engineering Consultant: Birikim Muhendislik Istanbul, Turkey Consulting Engineers: Boz Project Consulting Istanbul, Turkey Investor and Contractor: Orjin Group Dogus Group Joint Venture Istanbul, Turkey Greenheck

  • Model VersiVent

    Energy Recovery with Cooling and Heating VersiVent - Model VER • Commercial • Institutional • 2,000 - 10,000 cfm • 3.0 in. wg external static pressure • Configurable September 2008 Page Header 2 2 The VersiVent Model VER Advantage One Unit for Your Ventilation Needs The need for energy recovery in t