Search Results

Number of Results: 1441

Previous 21 22 23 24 25 Next Page 23 of 29
Results per page:
  • BCSW-FRP

    "Product Specification GuideModel Backward Curved Single Width FRP Centrifugal FansFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product sp

  • "EAD-401 (4"" Frame, Drainable Blade)"

    EAD-401 Adjustable Louver, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.125 in. (3 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned

  • Protecting Ventilation Openings for Storm Shelters and Tornado Safe Rooms; FEMA Louver Requirements (LA/101-19)

    P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2019 Greenheck Fan Corp. ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Louver Application LA/101-19 Protecting Ventilation Openings for Storm Shelters and Torna

  • TCB TCBRU TCBRS Belt Drive

    "Product Specification GuideModel Commercial Tubular Centrifugal FansFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specification gu

  • Warranty Statement for Kynar/Hylar and Mica Finish (70% PVDF)

    P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Louvers Architectural Finish Limited Warranty Kynar/Hylar and Mica (70% PVDF) Paint Greenheck warrants the finish of Kynar/Hylar (70% PVDF) paint for a period of 10 or 20 years (insert actual number of year

  • Understanding Bearings for the Fan Industry (FA/103-00)

    product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Fan Application FA/103-00 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399® Copyright © 2000 Greenheck Fan Corp. Understanding bearings for the fan i

  • Motor Starter Single Phase (MS-1P)

    "Product Specification GuideModel Motor Starter Single Phase (MS1P) ************************************************************************************************************************Note to User: This document is subject to copyright protection and is proprietary to Greenheck Fan Corporation.

  • Virtual-HVAC University Flyer

    Greenheck’s Virtual HVAC University HVAC University, Greenheck’s popular training program designed for engineers, will be temporarily offered in a virtual format. • Several one hour classes will be offered each week. • Live sessions led by Greenheck industry experts. • Classes incorporate interactiv

  • Marlins_Ball_Park_Miami_FL

    Greenheck Project Profile Marlins Park Miami, FL Mechanical Engineer: Populous Kansas City, MO General Contractor: Hunt/Moss, A Joint Venture Miami, FL Mechanical Contractor: John J. Kirlin, LLC Fort Lauderdale, FL Mechanical Subcontractor: United Sheet Metal Company Applegate USA, Inc. Pompano Beac

  • FD-100 and FD-300 Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel Static Fire DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ****************************************************************************************************Note to

  • Warranty for Duct Heater Products

    Damper Products Warranty Statement (12/12) Page 1 of 1 Copyright © 2012 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Duct Heater Products Greenheck Fan Corporation warrants this equipment to be free from defects in material a

  • Greenheck Test Switch (GTS)

    Greenheck Test Switches (GTS-1, GTS-2, GTS-3, and GTS-4) are used in dynamic smoke management systems containing Combination Fire Smoke Dampers. The GTS-1 and GTS-2 is a single control panel for use in dynamic smoke management systems to be used on combination fire smoke dampers equipped with TOR. T

  • steam_coils_opp_end

    OALL1 CAPACITY CLC1 STL CONNECTION SIZES MPTSWEATFPT NOTES RF SL2E C2 DATE TAG: APPROVED BY P.O. # W.O. # .006 CASING HEADERS COPPER ONLY 16 GA. GALV. STEEL 16 GA. STAINLESS STEEL 5/87/81 1/8 1 5/8 STEAM PRESSURE (psig) MODEL NO. CUSTOMER Performance Data CFMEATLAT .020.025 1314 ROWS AVAILABLE 8 FPI

  • Propeller Hooded Roof Fans - Series A (Model AE/AS)

    Propeller Hooded Roof Fans Series A - Model AE and AS Exhaust and Supply Fans April 2016 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 2 Model AE and AS Propeller Fans Table of Contents Standard Construction Features ...............4 Options and Accessories.....................5 Typical Installation ...

  • Double Gland Axle Seal Replacement

    Double Gland Axle Seal Replacement Instructions These instructions explain how to replace double gland axle seals in the field. Axle (shaft) penetrations through frame are protected by double gland stuffing boxes. Tighten as required to prevent leakage around axle. Caution: Over tightening will crea

  • QD-Cat_Dampers

    80 Model Best Available Program DFD-110, 150, DFD-150x10, DFD-150x12, DFD-150x14, DFD-150x16, FD-110, 150, FD-150x10, FD-150x12, FD-150x14, FD-150x16; DFD-310, 350; FD-310, 350; FDR-510; DFDR-510; DFD-210, DFDAF-310, 330; ODFD-150, OFD-150 1 Day SEDFD-210 3 Days FD-100, SSDFD-150, SSFD-150; FD-300,

  • "FAD-635 (6"" Frame, Drainable Adjustable)"

    FAD-635 Adjustable Louver, Drainable Blade Fabricated Steel Standard Construction Frame 6 in. (152 mm) x 16 gauge galvanized steel wall thickness Blades Drainable design, 16 gauge galvanized steel wall thickness, positioned at 35º on approximately 3.5 in. (89 mm) centers Seals Dual-durometer extrude

  • "GCE-402 (4"" Frame, Gravity Exhaust Damper)"

    GCE-402 Combination Exhaust Louver/Backdraft Damper, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 4 in. (102 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Louver blade: J style design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nomi

  • El_Platanal

    El Platanal Hydropower Plant Rio Cañete - Yauyos — Lima Peru, South America Engineering Firm: ARPL Technologia Industrial S.A. Lima, Perú Mechanical Contractor: SAEG PERU S.A. Lima, Perú Greenheck Representative: SAEG PERU S.A. Lima, Perú Provide fresh, comfortable air for workers in the plant’s mac

  • Microprocessor Controller TAP v2.10 (#475595 IOM) April 2014 (RVE, ERCH-01, ERT-01)

    "Program Features The microprocessor controller offers improved control through easy monitoring and adjustment of unit parameters by way of a lighted graphical display and a push-button keypad. Pre-Programmed Operating Sequences The controller has been pre-programmed to offer multiple control sequen

  • Model GRRS - Fire Ready Range Hood (#483299 IOM)

    "® Fire Ready Hood 1® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failur

  • Multiple Fan Systems - Fans in Series and Parallel (FA/115-02)

    "product application guide®A technical bulletin for engineers, contractors and students in the air movement and control industry. Fan Application FA/115-02 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2005 Greenheck Fan Corp. ® Multiple Fan Systems — Fans in Serie

  • Microprocessor Controller MUA v2.40 (#481747 IOM) September 2016

    "® Document 481747 Microprocessor Controller for Make-Up Air Products Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and oth

  • GJX

    "Product Specification GuideCommercial Axial Jet Fan, Model GJXFacility Services Subgroup: Division 23 (Previously Division 15) ************************************************************************************************************************Specifier Notes: This product specification guide is

  • Sure-Aire Catalog

    April 2019 Flow Monitoring System Sure-Aire™ for Centrifugal, Mixed Flow and Plenum Fans • Accurate • No System Effect • Reliable The Sure-Aire™ airflow monitoring system is ideal for HVAC applications where flow verification is required for proper system balancing, improving air quality, and controlli

  • Kitchen Fan Control Center (482413 IOM)

    "1Kitchen Fan Control Center ® ® Document 482413 Kitchen Fan Control Center Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself

  • Model ERCH (#476054 IOM)

    "® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with in

  • IGK (#472084 IOM)

    "Installation, Operation and Maintenance Manual Please read and save these instructions. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information. Failure to comply with instructions could result

  • Model BCF (#453284 IOM)

    ® Centrifugal Cabinet Fan 1® Document 453284 Model BCF Centrifugal Cabinet Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yours

  • Model APEX

    "Product Specification GuideGreenheck Model APEX – Packaged Air-to-Air Recovery Units with Optional Heating and/or coolingCSI MasterFormat Category 23 74 XX ************************************************************************************************************************Note to User: This docu

  • QD-Cat_PlenumFans

    53 www.greenheck.com Utility, Centrifugal and Radial Blowers For comprehensive product information, including performance, access the product catalog found on www.greenheck.com or contact your local Greenheck representative. Models APD, APH and APM Direct and Belt Drive Plenum fans are designed for

  • Warranty Statement for Kynar/Hylar and Mica Finish (70% PVDF) Galvaneal

    P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Louvers Architectural Finish Limited Warranty Kynar/Hylar and Mica (70% PVDF) Paint Greenheck warrants the finish of Kynar/Hylar (70% PVDF) paint for a period of 1 year from the date of product shipment whe

  • Belt Drive, Model RPBRF

    "Product Specification GuideModel RPBRF Belt Drive Hooded Roof Filtered Reversing Propeller FanFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes: This produ

  • CWA_projectprofile

    Greenheck Project Profile Central Wisconsin Airport (CWA) Mosinee, WI Engineering Firm: JDR Engineering, Inc. Madison, WI General Contractor: J.H. Findorff Son, Inc. Wausau, WI Mechanical Contractor: Best Mechanical Services Oshkosh, WI Greenheck Representative: Vyron Corporation Green Bay, WI Impro

  • Warranty Statement for All Damper Products

    Damper Products Warranty Statement (1/2019) Page 1 of 1 Copyright © 2019 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for All Damper Products Greenheck Fan Corporation warrants this equipment to be free from defects in material a

  • Selection Guide: Louvers

    Greenheck © January 2019 VIEW US ON CONTACT US LITERATUREGO TO eCAPS GREENHECK LOUVERS PRODUCT SELECTION GUIDE CONVENTIONAL STATIONARY OPERABLE WIND DRIVEN RAIN HURRICANE SPECIALTY LOUVERS PENTHOUSES Greenheck © January 2019 VIEW US ON CONTACT US LITERATUREGO TO eCAPS CONVENTIONAL STATIONARY EXTRUDE

  • BR-xx Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel BR-xx series Backdraft DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) *************************************************************************************************

  • Network Interface BMS v1.10 (#476811) April 2013

    "1Network Interface Controller for Tempered Air Products Reference Guide for the Network Interface Controller Please read and save these instructions. Read carefully before attempting to operate or maintain the product described. Protect yourself and others by observing all safety practices. Failure

  • Microprocessor Controller for Energy Recovery TAP v2.60 (#483232 IOM) January 2018

    ® Document 483232 Microprocessor Controller for Energy Recovery Microprocessor Controller for Tempered Air Products 1® Reference Guide for Microprocessor Controller Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintai

  • Blade Seal Replacement (HCDR Series)

    Blade Seal Replacement Instructions for HCDR series These instructions explain how to replace blade seals in the field. 1) Open damper. Energize the actuator, or disconnect actuator linkage so blade will remain open. Warning: Damper will close if actuator is de-energized. 2) Scrape existing seal from

  • HVAC_CourseGuide

    COURSE GUIDE COURSE GUIDE COR-001 Applying State-of-the-Art Engineering Technology in Manufacturing 1 This course will introduce you to state-of-the-art engineering technology for designing and manufacturing world class HVAC equipment. You will observe and tour an AMCA Air chamber and rapid prototyp

  • Sizing Air Conditioning Equipment to Maximize Energy Recovery Benefits (ERA/107-02)

    product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Energy Recovery Application ERA/107-02 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2002 Greenheck Fan Corp. ® Sizing Air Conditionin

  • SR5-XXX Series

    TorqPlusTM Electric Valve Actuators and Controls Torque 300 IN/LB – 1,600 IN/LB The Engineered Solution Bettis TorqPlus has taken the lead in offering compact, cost effective Spring Return Electric Actuator Packages. Three models offer a variety of solutions when one needs to protect a system upon l

  • MAC Suspension Mount Kit (#474907 IOM)

    "1 MAC Suspension Mount Kit ® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety information

  • "ESJ-155 (1 1/2"" Frame, J Blade)"

    Application and Design ESJ-155 is a thinline stationary louver commonly used for interior or exterior applications where high free area and low airflow resistance is required. The narrow depth makes this product ideal for installation into curtainwalls, windows, or as air conditioning grilles. Stand

  • Stationary Non-drainable Blade Louvers (#485607 IOM)

    ® Stationary, Non-Drainable Blade Louver Models 1® Document 485607 Stationary, Non-Drainable Blade Louvers Models ESJ-202, ESJ-401, ESJ-602, and ESK-402 Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to as

  • eCAPS Brochure

    eCAPS Quickly select and specify the best value products for your project. • Online and always up-to-date • Fast and efficient — compare multiple models simultaneously • Over 10,000 models and sizes of fans, 75 louver models and a damper selection guide • Simplified Dedicated Outdoor Air System (DOA

  • 7800 Series Relay Module

    ® U.S. Registered Trademark Copyright © 1998 Honeywell Inc. • All Rights Reserved CHECKOUT AND TEST 65-0229-1 7800 SERIES Relay Modules This publication provides general checkout and troubleshooting procedures for the 7800 SERIES Relay Modules. SYSTEM CHECKOUT IMPORTANT Perform all Static Checkout P

  • Adjustable Pressure Controller (APC) for EM Series

    EM-10, Horizontal Mount, Vertical Airflow Up EM-30, Vertical Mount, Horizontal Airflow EM-40, Horizontal Mount, Vertical Airflow Down Area Maximum Set Pressure (ft2) (m2) (in. wg) (Pa) 4 0.37 0.75 187 6 0.58 0.50 125 8 0.74 0.40 100 10 0.93 0.30 75 15 1.40 0.20 50 20 1.86 0.15 37 24 2.23 0.125 31 It

  • Quick Connect Breakaway Connection

    Quick Connect is used to connect a damper sleeve to a rectangular duct when a tight duct connection is required. The connector gives an airtight cross connection without the use of slip joints, and is an acceptable breakaway connection when installed properly. Particular attention should be given to

Previous 21 22 23 24 25 Next Page 23 of 29
Results per page: