Search Results

Number of Results: 1589

Previous 28 29 30 31 32 Next Page 30 of 32
Results per page:
  • What Sets Us Apart

    Designing your commercial kitchen ventilation project may seem complex. However Greenheck and our factory trained kitchen ventilation experts remove the complexity by providing engineering assistance, meeting codes and delivering reliable, quality components and systems on time. Our system approach

  • Model VSU

    "Product Specification GuideModelVSU– Packaged Make-Up Air Unit with Direct Gas-Fired Furnace For Outdoor or Indoor InstallationCSI MasterFormat Category 23 74 XX ************************************************************************************************************************Note to User: Thi

  • Fan Selection and Energy Savings

    H By BRIAN MLEZIVA Greenheck Fan Corp. Schofield, Wis. HVAC design engineers face many choices throughout the planning process, perhaps few as crucial as that of fan equipment, a principal consumer of energy. This article will discuss options for improving energy efficiency when designing an HVAC sy

  • Bracket Hinge Kit (#481366 IOM)

    Document 481366 Bracket Hinge Kit Centrifugal Downblast Exhaust - Sizes 060-200 Centrifugal Upblast Exhaust - Sizes 060-200 Bracket Hinge Kit Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, ins

  • High Temperature Exhaust (FA/109-01)

    "product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Fan Application FA/109-01 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2001 Greenheck Fan Corp. ® High Temperature Exhaust Many are

  • Model ERVe (#472119)

    ® Roof Curb and Duct Adaptor Assembly 1® Document 472119 Roof Curb and Duct Adapter Assembly Model ERVe Assembly and Installation Instructions Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product describe

  • DGK (#468695 IOM)

    ® Document 468695 Model DGK Make-Up Air Unit Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all saf

  • IDHB IDHC Specification

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel IDHB and IDHC Series Duct HeatersFacility Service Subgroup: 23 82 33 – Electric Duct Heaters *******************************************************************************************************

  • Frost Control for Energy Recovery Wheels (ERA/113-05)

    product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Energy Recovery Application ERA/113-05R P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2005 Greenheck Fan Corp. ® Frost Control for Ene

  • MaxitrolSeries14_iom

    "SERIES 14 INSTALLATION INSTRUCTIONS and field service check list Page 2 Introduction and Dimensions Page 3 Specifications Installation of Components Page 4 5 Field Service Checklist Page 6 Preliminary Circuit Analysis Low Fire Start Time Adjustment Sensitivity Adjustment Page 7 Wiring Diagrams Page

  • USCG Renewal Letter

  • Belt Drive, Model SAF

    "Product Specification GuideModel SAF Belt Driven Centrifugal Roof SupplyFacility Services Subgroup: Division 23 Section 23 34 23 ************************************************************************************************************************ Specifier Notes: This product specification guide

  • AFDW Specification

    "Product Specification GuideBelt Driven Airfoil Double Width Centrifugal Fan, Model AFDWFacility Services Subgroup: Division 23 (Previously Division 15) ****************************************************************************************************************************Specifier Notes: This p

  • Lighted Grille Conversion Kit (#482759 IOM)

    ® Document 482759 Lighted Grille Kit for Model SP Fans Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observi

  • Grand_Canyon_Univ_AZ

    Greenheck Project Profile Grand Canyon University College of Arts and Science Building Phoenix, AZ Mechanical Engineer: MSA Engineering Consultants Phoenix, AZ Contractor: Pono Construction Phoenix, AZ Subcontractor: Central Supply Metal Company Phoenix, AZ Architect: Orcutt | Winslow Phoenix, AZ Gr

  • Warranty Statement for Centrifugal Ceiling and Cabinet Exhaust - SP and CSP

    Centrifugal Ceiling and Cabinet Exhaust SP and CSP (12/12) Page 1 of 1 Copyright © 2012 Greenheck Fan Corporation P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Warranty Statement for Centrifugal Ceiling and Cabinet Exhaust – SP and CSP Greenheck Fan Corporation warrants its

  • New Test Standard for Dilution Blowers

    For reasons of safety and health, not to mention litigation, consulting and facility engineers have long insisted on independent performance verification for fans and blowers used in general HVAC, as well as more critical applications. With their unique discharge design, however, high plume dilution

  • O-Ring Axle Seal

    • O-ring Axle Seal Replacement, Rev 2, July 2020 Copyright 2020 © Greenheck Fan CorporationGFC As a result of our commitment to continuous improvement, Greenheck reserves the right to change specifications without notice. Product warranties can be found online at Greenheck.com, either on the specifi

  • ERV Application Manual

    "Energy Recovery Application Manual March 1997 Table of Contents Chapter 1: The Need for Mechanical Ventilation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 Chapter 2: The Enthalpy Wheel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

  • Model FPB

    Pressure Blowers Model FPB August 2008 Commercial Industrial Applications Page Header 2 Model FPB Model FPB Model FPB pressure blowers are suitable for clean air exhaust or supply applications. They utilize radial aluminum blade wheels to provide peak performance for systems that require low flow an

  • MPX (#472695 IOM)

    "General Safety Information DANGER • Always disconnect power before working on or near this equipment. Lock and tag the disconnect switch or breaker to prevent accidental power up. • If this unit is equipped with optional gas accessories, turn off gas supply whenever power is disconnected. CAUTION T

  • Closed Indicator Switch for Curtain Fire Dampers

    Rated Current 15A Switch Type Single pole, double throw type Operating Temperature -13°F to 176°F (-25°C to 80°C) See complete marking on product. UL 508 Classification E41515 The closed indicator switch is a high sensitivity hinge lever used on curtain fire dampers. When the damper blades close, th

  • GJX-36-160-0627 (pdf)

    0 30 30 15 0 -15 -30 60 90 120 [ft] 200 [fpm] Velocity [fpm] 1000 800 600 400 200 0 GJX-36-160-0627

  • README_Revit

    1 P.O. Box 410 Schofield, WI 54476 Phone: 715.359.6171 www.greenheck.com Thank you for downloading our Revit content! We are in the process of transitioning from providing Revit projects, to providing Revit family files from our eCAPS web platform. This pdf is a reference guide to assist you with co

  • IDHB and IDHE

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel IDHB, IDHE, IDHE-O Series Duct HeatersFacility Service Subgroup: 23 82 33 – Electric Duct Heaters **************************************************************************************************

  • CRD-2WT Series

    " P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel CRD-2WT Ceiling Radiation DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) **********************************************************************************************

  • General Conversion Table (TI/100-02)

    product application guide ® A technical bulletin for engineers, contractors and students in the air movement and control industry. Technical Information TI/100-02 P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2002 Greenheck Fan Corp. ® General Conversion Table This

  • "ECD-601 (6"" Frame, Exposed Linkage)"

    ECD-601 Combination Louver/Damper, Drainable Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.081 in. (2 mm) nominal wall thickness Blades Drainable design, heavy gauge extruded 6063-T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, po

  • Vertical Fan Coil (Model VFC) (#464696 IOM)

    ® Document 464696 Model VFCD and VFCB Vertical Fan Coil Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observ

  • Vektor-M Series VKCURB Fastener Kit (#1016011 IOM)

    1 Fastener Kit • Interior Section of Modular Roof Curb, Rev. 1, February 2018 Copyright 2018 © Greenheck Fan Corp. ® Document 1016011 Vektor-M Series Fastener Kit Interior Section of Modular Roof Curb Laboratory Exhaust System Assembly Instructions READ THROUGH THESE INSTRUCTIONS PRIOR TO STARTING A

  • Vektor-H and Vektor-HS with High Wind and Hurricane Certification

    Laboratory Exhaust Systems Vektor ®-H and Vektor ®-HS • High Wind and Hurricane Certification Miami-Dade NOA Certification The Vektor-H and Vektor-HS are the industry’s first laboratory exhaust fan systems to be certified to high wind standards. Advantages of NOA Certification • Pre-certified produc

  • EHH-501X (#475580 IOM)

    Part # 475580 Installation, Operation and Maintenance Instructions Model EHH-501X Copyright © 2012 Greenheck Fan Corporation Part# 475580 June 2012

  • Model DG / DGX Industrial Space Heating (#464044 IOM) (Pre-2009)

    Part # 464044 ® **WARNING** Disconnect and secure all electrical power to the “OFF” position prior to inspection or servicing. Failure to comply with this safety precaution could result in serious injury or death. **IMPORTANT** All factory provided lifting lugs must be used when lifting any unit. Fa

  • VCD-2xV, VCD-3xV and VCD-42V

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comf Product Specification GuideMODEL VCD-23V and VCD-3xV Control DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) *******************************************************************************************

  • QD-Cat_InlineandSidewallExhaustFans

    28 F C E A 1 in. B UL/cUL 705 Power Ventilators E40001 - BCF with TEFC motors E40001 - BDF with TEFC motors Dimensions for BCF Top horizontal discharge Model Size A B C E F 106 20 231⁄4 11 12 6 107 23 29 13 15 8 108 26 32 16 18 10 110 32 36 19 24 12 112 36 42 23 28 14 206 34 231⁄4 11 26 6 207 38 29

  • Model PVe

    " Product Specification GuideGreenheck Model PVe –– Heat Recovery VentilatorFor Outdoor or Indoor InstallationCSI MasterFormat Category 23 XX XX (Greenheck suggests the use of category 23 72 13) *********************************************************************************************************

  • Model RJ-6 x 9 (Pitched Roof Cap IOM)

  • FX10 Controller

    ® FX10 Controller Supplement Manual This supplement is intended to be used in conjunction with the IG/IGX Installation,Operation and Maintenance Manual (Document 470656). The FX10 controller is used on multiple furnace staged control units. The function and operation of the FX10 controller is the sa

  • HVLS Control - Keypad (#483885 IOM)

    ® High Volume, Low Speed Keypad Control® Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect yourself and others by observing all safety

  • HTOD Series (#479583 IOM)

    Receiving and Handling Upon receiving dampers, check for both obvious and hidden damage. If damage is found, record all necessary information on the bill of lading and file a claim with the final carrier. Check to be sure that all parts of the shipment, including accessories, are accounted for. Damp

  • Model TSU50 Weatherhood (#471095)

    ® Assembly Instructions PN 471095 Model TSU50 Weatherhood PARTS LIST Front Cover - Qty 1 Cover End - Qty 1 Lifting Lug - Qty 4 Right Side Panel Right Support Leg Top Cover - Qty 3 Top End Panel - Qty 2 Lifting Bracket Backing Plate - Qty 4 Left Side Panel Left Support Leg Back Retaining Angle - Qty

  • HCD-x30 Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel HCD – x3x Series Control DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) ***********************************************************************************************

  • Save Time and Money on Fan Installations

    ® FROM THE INSIDE OUT FROM THE INSIDE OUT A technical educational paper for engineers and contractors in the air movement and control industry. Industry White Papers P.O. Box 410 • Schofield, WI 54476 • 715.359.6171 • Fax 715.355.2399 Copyright © 2008 Greenheck Fan Corp. Save Time and Money on Fan I

  • HVAC University Course Guide

    COURSE GUIDE COURSE GUIDE COR-001 Applying State-of-the-Art Engineering Technology in Manufacturing 1 This course will introduce you to state-of-the-art engineering technology for designing and manufacturing world class HVAC equipment. You will observe and tour an AMCA Air chamber and rapid prototyp

  • Static Round Fire

    " P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.comProduct Specification GuideModel FDR-500 Series Round Static Fire DampersFacility Service Subgroup: Division 23 HVAC (Previously Division 15) ***************************************************************************************

  • SEBR-xx Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification GuideModel SEBR-xx series Backdraft DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) ***********************************************************************************************

  • MS-4209, MS-4309, MS-4709, MS-4809, MS8209, MS-8309

    SPECIFICATION DATA 38-00006-02 N314 MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators FOR FIRE/SMOKE CONTROL APPLICATIONS APPLICATION The MS4104, MS4109, MS4604, MS4609, MS8104, MS8109 Fast-Acting, Two-Position Actuators are spring return direct coupled actuators (DC

  • HPR-xxx Series

    "P.O. Box 410Schofield, WI 54476 Phone: 715.359.6171www.greenheck.com Product Specification Guide Model HPR-xxx Series Pressure Relief DampersFacility Service SubGroup: Division 23 HVAC (Previously Division 15) ****************************************************************************************

  • Model USGF (#462077 IOM)

    ® Ultimate Steel Grease Fan 1® Document 462077 Model USGF Ultimate Steel Grease Fan Installation, Operation and Maintenance Manual Please read and save these instructions for future reference. Read carefully before attempting to assemble, install, operate or maintain the product described. Protect y

  • "EAH-690 (6"" Frame, High Free Area)"

    EAH-690 Adjustable Louver, J Blade Extruded Aluminum Standard Construction Frame Heavy gauge extruded 6063-T5 aluminum, 6 in. (152 mm) x 0.125 in. (3 mm) nominal wall thickness Blades J style design, heavy gauge extruded 6063T5 aluminum, 0.081 in. (2 mm) nominal wall thickness, positioned 45º or 90º

Previous 28 29 30 31 32 Next Page 30 of 32
Results per page: